2 x 0 V to 30 V/0 A to 2 A
1 x 5 V/2 A
(130 W)
Linear regulated, two-quadrant power supply
(current source and sink)
Real-time voltage and current values
Setting and read-back resolution: 10 mV / 1 mA
Advanced parallel- and serial operation
Front connectors: 4 mm safety sockets
SENSE connectors for line loss compensation (30V channels)
External modulation of output voltages up to 50 kHz
Arbitrary module: 4096 points, 12 bit
PC software (free of charge) to easily create user-defined waveforms
RS-232/USB dual interface, IEEE-488 (GPIB) optional
2 x 0
V to 32
V
/
0
A to 2
A
1 x 0
V to 5.5
V
/
0
A to 5
A
(155 W)
Low residual ripple due to linear post-regulators
Real-time voltage and current values
Setting and read-back resolution: 10
mV / 1
mA
Advanced parallel- and serial operation
Adjustable over-voltage protection (OVP)
Front connectors: 4
mm safety sockets
Temperature-controlled fan management
HM8143 Three-Channel Arbitrary Power Supply
HM7042 - 5 Three-Channel Power Supply
HMP Series Programmable High-Performance Power Supplies
HMP series
model overview:
HMP4040
HMP4030
HMP2030
HMP2020
Output values
4 x 0 V to 32 V / 0 A to 10 A
3 x 0 V to 32 V / 0 A to 10 A
3 x 0 V to 32 V / 0 A to 5 A
1 x 0 V to 32 V / 0 A to10 A,
1 x 0 V to 32 V / 0 A to 5 A
Output power
384 W
188 W
Channels
4
3
3
2
HM8115-2 Power Consumption Meter 8
kW
Measurement range: 1 mW to 8 kW
Voltages from 100 mV to 500 V, currents from 1 mA to 16 A
Frequency range: DC to 1 kHz
Simultaneous display of voltage, current and power
(W, var, VA or power factor) values
Auto-ranging for easy measurement
Suitable for measurements on frequency converters
MONITOR (BNC) shows instantaneous power value
RS-232/USB dual interface, IEEE-488 (GPIB) optional
PC software (free of charge) for automated long-term data acquisition
included
Adapter (10A fused) for easy measurement
of mains voltage, current and power
consumption to use with HM8115-2.
HZ815 Power Adapter
for HM8115-2
HMP4040 | HMP4030 - Four/Three-Channel Models
HMP2030 | HMP2020 - Three/Two-Channel Models
Low residual ripple due to linear post-regulators
Real-time voltage, current and watt values
High setting and read-back resolution: 1 mV and 0.1 / 0.2 / 1.0 mA
(current output and model dependent)
FuseLink (electronic fuses) freely combinable for all channels
FuseDelay tuneable up to 250 ms
EasyArb function directly programmable at the device
PC software (free of charge) to easily create user-defined waveforms
Independently adjustable over-voltage protection (OVP) for each channel
Advanced parallel- and serial operation through V/I tracking
Front connectors: 4 mm safety sockets
Rear connectors for all channels including SENSE
RS-232/USB dual interface, remote control via SCPI based commands