background image

More information

 | www.hameg.com  

5

Precise Signal Analysis

An excellent sampling rate in combination with a large memory depth is the key 
for precise signal analysis. The highly resolved measurement data and the  
powerful zoom function expose even minor signal details.

Depending on their requirements users can choose between three 2-channel-
versions and three 4-channel-versions with bandwidths  between 300 and 
500 MHz.

500 MHz

400 MHz

300 MHz

4 channel

HMO3054

HMO3044

HMO3034

2 channel

HMO3052

HMO3042

HMO3032

4  HAMEG INSTRUMENTS

 | HMO3000 SERIES

Bandwidth Upgrade

Should your requirements change, then so does the HMO3000, as the 300  
and 400 MHz models can be extended to 500 MHz bandwidth via software  
upgrades whenever required.

 ❙For 300 MHz models with options  

HOO352 (2 channel) and HOO354 (4 channel).

 ❙For 400 MHz models with options  

HOO452 (2 channel) and HOO454 (4 channel).

Options

HOO352 / HOO354

HOO452 / HOO454

Key facts

Sampling rate (per analog channel)

2 GSa/s

Maximum sampling rate

4 GSa/s

Memory depth per channel

4 MPts.

Maximum memory

8 MPts.

Maximum number of logic channels

16

Input impedance

1 MΩ / 50 Ω

V/div. @1 MΩ

1 mV/div.  to  5 V/div.

V/div. @50 Ω

1 mV/div.  to  1 V/div.

Upgrade at any time

HMO 3000  Series

500 MHz

300 MHz  |  400 MHz

300 MHz 

>>>

 

500 MHz

400 MHz 

>>>

500 MHz

Содержание HMO3000 Series

Страница 1: ...Mixed Signal Oscilloscopes 300MHz 400MHz 500MHz HMO3000 Series...

Страница 2: ...are permanently updated and displayed Fan Maximum noise reduction by temperature controlled fan Zoom Memory zoom up to 200 000 1 Analog channels Vertical sensitivity of up to 1mV div Bus signal sourc...

Страница 3: ...G INSTRUMENTS HMO3000 SERIES Bandwidth Upgrade Should your requirements change then so does the HMO3000 as the 300 and 400MHz models can be extended to 500MHz bandwidth via software upgrades whenever...

Страница 4: ...nal types on one monitor As shown in the image below the latency time of a DAC can be determined with one simple cursor measurement Therefore a MSO allows developers to devote their full attention to...

Страница 5: ...P mode at a later time However at that point many oscilloscopes with FFT functionality calculate the spectrum only once and store the result in the memory The base time signal will no longer be used f...

Страница 6: ...Variable Between calibrated steps Inputs CH1 CH2 CH1 to CH4 Impedance 1M II 13pF 2pF 50 switchable Coupling DC AC GND Max input voltage 1M 200Vp derates at 20dB Decade to 5Vrms above 100kHz 50 5Vrms m...

Страница 7: ...nnels 16 x 1GSa s Resolution vertical 8Bit HiRes 10Bit Memory 2 x 4MPts 4 x 4MPts 1x 8MPts 2 x 8MPts Operation modes Refresh Average 1024 Envelope Peak Detect 500ps Filter Rol free run triggered from...

Страница 8: ...sensitivity up to 1mV div Trigger modes slope A B pulse width video logic serial buses optional Serial bus trigger and hardware accelerated decode incl list view Options I2 C SPI UART RS 232 HOO10 HOO...

Страница 9: ...9 0 61828000 www hameg com R S is a registered trademark of Rohde Schwarz GmbH Co KG HAMEG Instruments is a registered trademark of HAMEG Instruments GmbH Trade names are trademarks of the owners 11 2...