42
Subject to change without notice
AUX pushbutton
This pushbutton belongs to the AUXILIARY INPUT
. The ope-
ning of the menu depends upon the actual operating mode.
36.1 Analog mode
36.1.1
AUXILIARY INPUT
is the external trigger input. For
setting external triggering press SOURCE
, select the „Trig.
Source“ menu, then „External“.
36.1.2
If „External“ triggering was not selected the menu „Z
Input“ will open up. If „Off“ is chosen AUXILIARY INPUT
has
no function. If „On“ is chosen it will function as Z input i.e. in-
tensity modulation input. This input is destined for TTL signals,
a voltage of
>
1 V
p
will turn off the trace.
36.2 DSO mode
36.2.1
In DSO mode the AUX pushbutton is deactivated and the
AUXILIARY INPUT
can only serve as an input for external
trigger signals.
AUXILIARY INPUT
(BNC connector)
In DSO mode this connector can be used as external trigger
input.
In analog mode it can serve as external trigger or Z-axis (in-
tensity modulation) input.
The connector housing is connected to the instrument housing
and thus to safety ground. Although the ring around the connec-
tor has no function, no voltage may be applied here.
C o n t r o l s a n d R e a d o u t
PROBE ADJ. – connector
A square wave signal of 0.2 V
pp
is available for the adjustment
of 10 : 1 probes. The frequency can be selected by pressing
the pushbutton PROBE ADJ. and calling the menu ”Utilities“.
Further information may be found in the section ”Probe adjust-
ment and use“ in the chapter ”Operation and pre-settings“.
PROBE ADJ – pushbutton
This pushbutton produces the menu ”Utilities“, two options
are available:
39.1 COMP. Tester On Off.
If ”On“ is chosen analog mode is selected automatically. A trace
and a readout display ”Component Tester“ will appear.
In this mode the 4 mm connectors labelled ”COMPONENT
TESTER“ become the measuring input. See also the chapter
”Component Tester“.
Choosing ”Off“ will return the instrument to all former set-
tings.
39.2 Calibrator 1kHz 1MHz
Depending on the setting the square wave signal frequency at
the PROBE ADJ – socket is 1 kHz or 1 MHz.
COMPONENT TESTER - (sockets)
Both 4 mm diameter sockets serve as a two pole input for
component test. Further information can be found under section
Component Tester.
AUXILIARY INPUT
TRIGGER
EXTERN
Z-INPUT
AUX
1M
Ω
II
15pF
max
100 Vp
INPUTS
1M
Ω
II15pF
max
400 Vp
X-INP
CH 1
VERT/XY
CH 2
HOR
MAG
CAT I
!
CAT I
!
VAR
VAR
VAR
x10
POWER
36
37
29
35
34
31
32
33
30
MEMORY
oom
COMPONENT
TESTER
PROBE
ADJ
C O M B I S C O P E
1 : 1 / 10 / 100
CH I: 500 mV
POWER
39
40
38