Digital radiography system, dental   C10819 Series

Hamamatsu Photonics K. K.

Precautions when using (safe and secure) Electronic Medical Equipment

1. User must read the manual and learn how to use.

Or please use it under the supervision of user who
knows usage.

2. Take care of the following while installing the equip-

ment. Install in a dry place.

(1) Keep in a place where there are no adverse

effects due to atmosphere containing pres-
sure, heat, humidity, air passage, direct sun-
light, dust, salt content or sulfur content.

(2) Take care of the safety status such as the

angle of inclination, vibrations, shocks (includ-
ing handling time), etc.

(3) Do not use in places where chemicals are

stored or where there is generation of gases.

3. Take care of the following before using the equip-

ment.

(1) Confirm that the equipment is running properly

by checking the switch position, display cate-
gory etc.

(2) Confirm that all the cables are correctly and

safely connected.

(3) Take sufficient precautions since using the

equipment widely would risk in errors in the
precise measurements and might create dan-
gers.

(4) Recheck the external circuits that are directly

connected to the patients.

4. Take care of the following while using the equipment.

(1) Do not exceed the necessary time for mea-

surement.

(2) Constantly monitor that there are no abnor-

malities in the entire equipment and to the
patients.

(3) In case any abnormalities are detected in the

equipment or the patient, take appropriate
measures such as stopping the operation of
the equipment while the patient is in a safe
state.

5. Take care of the following after using the equipment.

(1) Shut-off after returning the operational

switches to the original positions as before
according to the determined procedures.

(2) When removing the cords, do so without

applying unreasonable extra strength. 

(3) Take care of the following incase storage is

necessary.
I. Store in a dry place.
II. Store in places where there are no adverse

effects due to atmosphere containing pres-
sure, heat, humidity, air passage, direct
sunlight, dust, salt or sulfur.

III. Do not store in places where chemicals are

stored or where there is generation of
gases.

(4) Align and arrange after cleaning the accesso-

ries, cords, etc.

(5) Always clean the equipment so that there are

no breakdowns when using it again.

6. In case of a breakdown, do not fiddle on your own

discretion, 
perform the appropriate display and entrust the
repairing to a technician.

7. Do not modify the equipment.

8. Maintenance check

Always check the equipment and the parts.
When using equipment that has not been used for a
while, confirm that the equipment is operating nor-
mally and safely before reuse it.

9. Others

(1) Operate properly in accordance with the

Instruction Manual.

Содержание C10819 Series

Страница 1: ...o operate this product by methods different from those described in this instruction manual may cause serious accidents Keep this instruction manual near the product for easy reference when needed Instruction Manual COPYRIGHT HAMAMATSU PHOTONICS K K Version 1 01 Document Number K46 B60035 Document Revision 1 02 18 Sep 2009 0120 ...

Страница 2: ...surement 2 Constantly monitor that there are no abnor malities in the entire equipment and to the patients 3 In case any abnormalities are detected in the equipment or the patient take appropriate measures such as stopping the operation of the equipment while the patient is in a safe state 5 Take care of the following after using the equipment 1 Shut off after returning the operational switches to...

Страница 3: ...tuation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices This symbol means follow to operating instructions Type B Equipment Legal manufacturer for EU market Authorized repersentative in the European Community CE marking for conformity of 2007 42 EC 0120 Notified Body No SGS United Kingdom Limited Serial number CLASSII Equipment EC R...

Страница 4: ...4 Description of the External appearance and Various parts 11 4 1 Sensor Unit 11 4 2 Main Unit 12 5 Setup 13 5 1 System Configuration 13 5 2 Equipment Connection 14 5 3 Driver Installation 15 5 4 Installation of Application software 21 6 Product Specifications 22 6 1 Specifications 22 6 2 Functions 23 6 3 Data Acquisition Timing Chart 25 6 4 Dimensions 26 7 Maintenance 29 7 1 Repair 29 7 2 Mainten...

Страница 5: ... 01 Main unit S10810 sensor unit C10819 02 Main unit S10811 sensor unit Main Unit This product main unit is loaded with various types of Digital Signal Processing Cir cuits starting with 12bitADC This product is also loaded with Sub array binning 2X2 function Gain adjustment function and Offset adjustment function in order to reduce the image data size and the transmission time This product is use...

Страница 6: ...ation with respect to the Protection System Degree of Protection against elec tric shock Caution When determining the diagnosis and the treatment of a patient do not rely on the data of this product alone and determine in combi nation with other clinical indications or data etc Caution The Equipments Computer etc used for connecting with this product must conform to IEC60950 1 and ensure safe volt...

Страница 7: ...ustible Gases High density Oxygen etc 2 4 Labeling The CE mark is a mark which is attached to satisfy the standard of EU member nation Sensor unit The upper surface of sensor unit connector Main unit Base of the main unit Caution Do not allow any penetration of Liquids into the main unit Danger of causing main unit malfunctions Caution Do not use in Combustible Environment Combustible Gases High d...

Страница 8: ...uch as damp cloth or spray etc Always use the included USB cables The sensor unit might get damaged due to Static electricity Do not touch the Connector pins When the sensor unit is not connected to the main unit cover the connectors and keep the pins safe Do not keep anything on the Sensor Do not apply any pressure to the sensor unit The sensor unit can get damaged due to the pressure applied Hae...

Страница 9: ...by the same procedure The person clicking the pictures Doctor or Technician must follow the correct Radiation Hygiene Procedures Please study the method of use of this product before using Please check and confirm that the case cable etc are in good conditions each day before start working Please lightly wipe cloth to 70 isopropyl alcohol and clean it everyday If ground is not done and power break...

Страница 10: ...ture 0 ºC to 40 ºC During operation Relative humidity Below 70 During operation Caution Do not store or operate in the following places Places with sharp temperature changes Places with direct sunlight Near heating appliances Near things generating high intensity magnetism or radio waves Places with vibrations Places touching corrosive gases Chlorine fluorine etc Places with dust ...

Страница 11: ...or controlling C10819 Signal processing unit for Windows 2000 XP Library software for controlling C10819 Signal processing unit for Windows 2000 XP Application software for Data measurement for Windows 2000 XP Various Instruction Manuals C10819 Series Instruction Manual C10819 Series Application Software Instruction Manual DCamLibM DLL Manual DCamImg DLL Manual ...

Страница 12: ...ra tion is output through the Connector 36pin MDR Connector This is a high density 36pin MDR for connecting with the main unit The Bias volt age and various Clock signals are provided by the main unit through the connector Also Analog video signal depending on the X ray radiation intensity and a timing signal H CMOS logic level signal that is in synchronization with the X ray radiation duration is...

Страница 13: ...various setups are performed and the X ray image data that is converted into digital signals is also transmitted Status Display LED It is a LED which displays the current operational mode of the main unit The rela tion between the display and operational mode are as follows These are all dis played by green Refer to 6 2 Functions and Operational mode for details of the various modes LED Display Op...

Страница 14: ...ations CPU Intel Pentium 4 Above 2 6GHz Intel Pentium M Above 1 4GHz RAM Above 512MB HDD Above 3MB However it is the required space at the time of software installation and may change depending on the usage status CD ROM Drive Used at the time of software installation I F USB2 0 1 Display XGA above 1024 768 OS Microsoft Windows 2000 SP4 or later XP SP1 or later ...

Страница 15: ...the equipment by referring to the following procedure 1 Connect the 36pin MDR connector of the sensor unit to the SENSOR connector of the main unit 2 Connect B connector of the USB cable to the USB connector of the main unit 3 Connect the A connector of the USB cable to the USB port of the PC 1 2 3 ...

Страница 16: ...cessary The installation method of this software varies slightly depending on the OS Install the Device Driver by referring to the following installation methods based on the OS For Windows2000 1 When PC is started after the completion of 5 2 Equipment connection the screen of the detection of New hardware is displayed and Found New Hardware Wizard appears and then click Next ...

Страница 17: ...hat HPK C10819 is dis played in This wizard will complete the installation for this device click the radio button for Search for a suitable driver for my device recommended and then click Next 3 In the Locate Driver Files window insert the CD in the CD ROM drive select the check box of CD ROM drives and click Next ...

Страница 18: ...ow verify that HPK C10819 and usb camif inf is shown in the location of the driver then click Next 5 After the necessary files are copied confirm the Completing the Found New Hard ware Wizard and HAMAMATSU USB Camera Module screens and then click Finish With this the driver installation is complete ...

Страница 19: ... C10819 Series 6 After the installation is complete right click on My computer and select Proper ties The system properties will be displayed refer the Device Manager in the Hardware tab and confirm that HAMAMATSU USB Camera Module is displayed ...

Страница 20: ...Wizard is started confirm that HPK C10819 is displayed click the radio button for Install from a list or specific location Advanced and click Next 2 In the Please choose your search and installation options window click the radio button for Search for the best driver in these locations select the checkbox for Search removable media floppy CD ROM and click Next ...

Страница 21: ...are Wizard and HAMAMATSU USB Camera Module screens and then click Finish This completes the driver installation 4 After the installation is complete right click on My computer and select Proper ties The system properties will be displayed open the Device Manager in the Hardware tab and confirm that HAMAMATSU USB Camera Module is displayed ...

Страница 22: ...is product the control of the sensor unit main unit and X ray imaging is per formed by the supplied application software Please refer C10819 Series Control Software Instruction Manual K46 B60037 inside the included CD ROM for the installation method and the method of use of the supplied application software ...

Страница 23: ...esolution 15 Lp mm Min 15 Lp mm Min Scan rate 1MHz Frame read time 1 62sec 2 18sec Data Transmission Time 1 61sec 2 17sec Total Transmission Time 1 62sec 2 18sec AD Resolution Power 12bits 4095ADU Conversion Gain 48 8e ADU Read Noise 7 0ADU Dynamic Range 585 Memory Size 4MByte Main Unit I F USB2 0 Power Provided by the USB Connector bus powered Storage Ambient Temperature 20 ºC 70 ºC Operational A...

Страница 24: ...s to be reduced by reducing the image data size However the resolution is reduced when this function is used The default value is 1x1 Data Acquisition Mode This function sets up the operational mode for data acquisition Among the opera tional modes there are basically 2 modes viz internal synchronization mode oper ated by software trigger and external trigger mode that operate in synchronization w...

Страница 25: ... the range of 1 to 65 535 msec However in case of External Trigger Edge Mode EXT EDGE1 the accumulation time is in the range of 41 to 65 535 msec Also this setup is valid only when the Internal Synchro nization Mode INT and External Trigger Edge Mode EXT EDGE1 are setup This setup value corresponds to the Exposure Time of 6 3 Data Acquisition Timing Chart Operational mode This function allows the ...

Страница 26: ...ode EXT LEVEL1 Mode Trigger In Software Exposure Signal Exposure Time P1V P2V P1H P2H AD Conversion Data Transfer USB2 0 Data Acquisition Time Data Transfer Time Exposure Time Data Acquisition Time Data Transfer Time External Trigger In from Sensor Exposure Signal P1V P2V P1H P2H AD Conversion Data Transfer USB2 0 Dummy Scan Exposure Time Data Acquisition Time Data Transfer Time Dummy Scan Externa...

Страница 27: ...10819 Series 6 4 Dimensions 6 4 1 Sensor Unit S10810 Overall View Sensor 18 17 2 36 35 20 19 PIN No 1 CCD SENSOR MDR CONNECTOR 3M 10136 3000VE 36 TERMINALS FERRITE CABLE 2 000 SHROUD 9 40 5 30 41 0 30 0 6 85 4 15 20 0 26 4 3 2 3 2 3 5 9 40 5 30 CABLE ACTIVE AREA ...

Страница 28: ...phy system dental C10819 Series S10811 Overall View Sensor 13 5 5 8 13 5 5 8 42 3 34 0 3 0 5 3 24 0 30 0 3 0 3 0 3 5 18 17 2 36 35 20 19 PIN No 1 CCD SENSOR MDR CONNECTOR 3M 10136 3000VE 36 TERMINALS FERRITE CABLE 2 000 SHROUD CABLE ACTIVE AREA ...

Страница 29: ...Product Specifications 28 Digital radiography system dental C10819 Series 6 4 2 Main Unit 115 125 32 SENSOR STATUS ...

Страница 30: ...by technicians authorized by the maker 7 2 Maintenance Service life Please change the sensor unit within 5 years or 100 000 times of use 7 3 Cleaning In order to keep this product clean wipe the sensor unit with the specified chemical 70 of Isopropyl Alcohol and the outer covering of main unit with a slightly damp cloth ...

Страница 31: ...hat the symptoms are defined while avoiding any mistakes and mis conceptions If there is no error and the situation is not improved please contact us our company or the authorize dealer after confirmation of next list and others A concrete symptom example The unit is hot Acquiring image is impossible The outbreak time 3 Exclusion of repair Repair is done based on your requests but there are cases ...

Страница 32: ...de MDR Mini D Ribbon It is the high density type D Shell Connector of the Ribbon Type Bellows type UPS Uninterruptible Power Supply Uninterruptible Power Supply USB2 0 Universal Serial Bus The specification of data transmission channel connecting peripheral device and personal computer The 1 type of the transmission mode in USB2 0 is HS High Speed Mode 480Mbps XGA eXtended Graphics Array Display s...

Страница 33: ...cquisition mode set as the mode in use Verify the data acquisition mode in use and set 3 Is the external trigger polarity set as in use Verify the external trigger polarity in use and set 4 Is the accumulation time set properly Verify accumulation time value setting 5 Is the gain value set properly Verify the gain setting 6 Is the offset value set properly Verify the Offset setting If you still ha...

Страница 34: ...the attached USB cable If LED of main unit is on there are possibilities of disconnection and damage of USB cable Then please contact sales representative Now change the USB connector of the connected PC with the other USB connector If LED of main unit is on there is possibility of breakdown in USB con nector of PC Please verify Connect to the other PC If LED of main unit is on there is possibilit...

Страница 35: ...ger level mode EXT LEVEL1 mode If the data acquisition mode in use is other than the external trigger level mode then set the data acquisition mode to be used internal synchronous mode INT mode external trigger edge mode EXT EDGE1 mode If the data acquisition mode is in use is external trigger level mode then accumulation time setting is not required and so there will not be a problem if it is not...

Страница 36: ...tinuous imaging is not possible Answer Is continuous imaging performed with short accumulation time When the image data is large the data processing fails to meet the stipulated deadline and the imaging is not performed Perform the imaging by increasing the accumulation time ...

Страница 37: ... Danger mark 2 Warning mark Added the following symbol mark 1 CE0120 mark 2 Factory mark 3 EC REP mark 4 i reference mark Corrected the following contents 1 Information of Caution mark 2 2 4 Labeling Changed the label image of main unit 3 3 Accessories Changed the image of Package Insert 4 5 4 Installation of Application software Changed the name of software instruction manual and added the i mark...

Страница 38: ...re Intel Corporation trademarks or registered trademarks Manufacturer European Sales Representative Hamamatsu Photonics KK Hamamatsu Photonics Deutschland GmbH Head Office 1126 1 Ichino Cho Higashi Ku Hamamatsu City Shizuoka Pref 435 8558 Japan Phone 81 53 434 3311 Fax 81 53 434 5184 Arzbergerstr 10 D 82211 Herrsch ing am Ammersee Germany Phone 49 8152 375 0 Fax 49 8152 265 8 Document Number K46 B...

Отзывы: