Installation
•
Indoors only
•
Ambient humidity: less than 85%
•
Ambient temperature: 32-104°F
•
Altitude: lower than 3,280 feet
Operation
1. Plug the power cord into a power source
Red cord is plus pole. Blue cord is negative pole.
2. Press the “UP” foot switch to raise the lift.
3. Press the “DOWN” foot switch to lower the lift.
4. Release the foot switch to stop movement.
5. When the table reaches its upper or lower limit, the limit switch stops it
automatically. The second time the limit switch is triggered after the power
is turned on, the table decelerates and stops just short of that limit point.
CAUTION
•
Use with adequate margin to avoid exceeding maximum regulation usage frequency.
•
The electromagnetic brake makes a clicking sound as it opens and closes during table height
adjustment and is normal.
•
Immediately release switch when table reaches its upper or lower limit to avoid triggering the alarm.
CAUTION
The upper- and lower-end limit switches are set to their limit values at the factory. When adjusting them,
be careful not to exceed their limits to avoid damage.
Alarm Display
An internal microcomputer continuously monitors safety levels. If a hazard or abnormality is detected, the foot
switch lamp lights to indicate the location. If the alarm display appears, immediately stop operation, find the
cause and resolve the issue.