14
4.2
Regular maintenance
-
Users must exclusively carry out the maintenance work and checks listed below.
-
Clean the spray gun cleaner regularly
-
Clean or replace the paint stop filter on the black hose regularly
-
Clean the work surface
-
Clean the air and steam extraction on the inside of the machine
-
Clean the shift rod on the safety valve of paint residues, etc.
-
Clean the collection basin
-
Clean and rinse the bottom of the collection basin after each use once the solvent has drained.
All other maintenance and repair work must be carried out by a suitable, qualified specialist.
WARNING! At least once a year, the HR
3000 must be thoroughly serviced by a
specialist qualified by the manufacturer. Defective or damaged parts must be replaced
immediately and exclusively with original parts.
4.3
Errors and troubleshooting
-
Should one of the cleaning cycles not be executed completely, it is recommended that the points in
Sections 4.1 and 4.2 be carried out.
-
If, despite these steps, the HR 3000 still fails to operate correctly, disconnect the compressed air
and set the main lever to the “0” position.
-
Then inform the supplier or the manufacturer of the HR 3000 so that qualified personnel can carry
out troubleshooting.
4.4
Spare parts list
-
1 earthing cable
-
1 empty container DIN 61 (20 l)
-
1 cleaning brush
-
1 manual.
-
1 hazard warning sticker.
5
Technical documentation
5.1
Technical data
Weight:
70 kg
Dimensions (HxDxW):
1580 x 600 x 840 mm
Dimensions of cleaning tank (HxW):
400 x 400 mm
Dimensions of working surface (HxDxW):
400 x 350 x 400 mm
Solvent capacity:
20 l
Suction connection:
180 mm
Required extraction volume
700 m³/h
Number of guns per wash:
2
Air pressure:
4
–
5 bar
Number of containers in base:
2
Air speed suction cap input:
0.52 m/sec
Sound pressure (ISO 3746:2010)
70 dB(A)
Noise level
The noise level is measured with an empty HR
3000 while operating using a noise level meter
with integrator.
The measurements were carried out by a qualified laboratory employee in accordance with EN ISO
standard 3746:2010. The results are:
-
Acoustic pressure equivalent in the centre of the control panel
LpA = 70 dB(A)
-
Acoustic pressure equivalent medium level
LpAm = 68 dB(A)
5.2
Risk assessment
A risk assessment for assembly and operation is available on request from EMM International.