Halyard Exhaust Alert Mk3 Скачать руководство пользователя страница 9

 

 

Exhaust Alert Operating & Fitting Instructions 

 

HMI 201/01 

Section 4

 

Wiring & Connections  

Refer to appropriate wiring diagram. 

4.1

 

Connection Block 

 

Connection 1 is the common negative (-ve) for the unit, sensors, controls and 
sirens. 

 

Connections 2 (engine 1) and 3 (engine 2) are positive (+ve) supply (12/24V) 
to the unit from engine 1 and 2 ignition circuits.  The unit uses this supply to 
identify which engine is running.  These feeds must be protected using the 
fuse holders and 1A fuses supplied. 

 

Connection 7 is for the Repeater guage or the optional 120db siren positive 
(+ve). 

 

The Repeater Gauge connects to 8,9,10,11 and 1 

 

Connections 4,5 & 1 are for exhaust sensors for two engines, each with one 
pair of wires. For a single sensor system then the connection for the second 
sensor (connection 5) should be connected directly to earth (connection 1), 

 

Connection 

12 activates the unit’s night mode, d

imming  LEDs  to  preserve 

night vision (+ve to dim). 

4.2

 

Wiring Master Gauge 

 

Remove approximately 80mm of the outer sheathing from the Master gauge 
loom. 

 

Remove 8mm of insulation of each core wire. 

 

Lightly  twist  the  strands  of  each  core  and  insert  into  the  appropriate 
connection block position.  

 

Connect the wires from the gauge unit to the connector block as follows and 
tighten the clamping screws:

 

Connection 
Block 
Number 

Wire Colour 

 Description 

Required 
Wire size 

Black 

Common -ve 

0.75mm

2

 

Green 

Engine 1 +ve 

0.75mm

2

 

Turquoise 

Engine 2 +ve 

0.75mm

2

 

Orange 

Engine 1 ve 

Halyard 
Supplied 

Red 

Engine 2 ve 

Halyard 
Supplied 

Yellow 

No connection 

 

Slate Grey 

Repeater gauge buzzer or 
Optional 120 dB siren +ve 

0.75mm

2

 

White  

Optional repeater gauge 

0.75mm

2

 

Blue  

Optional repeater gauge 

0.75mm

2

 

10 

Brown  

Optional repeater gauge 

0.75mm

2

 

11 

Purple  

Optional repeater gauge 

0.75mm

2

 

12 

Pink 

Night Mode input (+ve to 
dim) 

0.75mm

2

 

CAUTION:  

Follow the wiring 
instructions carefully 
and check the 
connections against 
the correct wiring 
diagram on page 7 
before connecting the 
power. Incorrect 
connections could 
damage the unit. 

CAUTION:  

When removing the 
outer sheathing take 
care not to damage 
the insulation of the 
individual core wires 
underneath. 

Содержание Exhaust Alert Mk3

Страница 1: ...Exhaust Alert Mk3 Installation Operating Instructions THE SCIENCE OF SILENCE Halyard 2020 All Rights Reserved...

Страница 2: ...the Components 4 3 1 Fitting the sensor 4 3 2 Fitting the Connection Block 5 3 3 Fitting the Master Gauge 5 Section 4 Wiring Connections 7 4 1 Connection Block 7 4 2 Wiring Master Gauge 7 4 3 Circuit...

Страница 3: ...m careless use of hand tools lifting equipment power tools or unaccepted maintenance or working practices Because of the possible danger to persons or property from accidents that may result from the...

Страница 4: ...t system immediately after the engine exhaust outlet The cooling water reduces the temperature of the exhaust system and reduces exhaust noise Should the cooling water flow be blocked or substantially...

Страница 5: ...hs Electrical tie wraps or cable clips to secure the wiring to suitable supports A small electrical screwdriver to fit the terminals on the connection block Spanners to fix the sensors to the flexible...

Страница 6: ...xhaust elbow as detailed in Fig 2 Tidy up the edges of the hole as necessary Identify the correct components from the sensor kit as per Fig 1 Fit rubber grommet G into the centre of one of the large p...

Страница 7: ...fy 12V 24V dc power source Typically this is the ignition circuit of each engine to be monitored but it can be from an independent switch power source Secure the Connection block to a bulkhead or othe...

Страница 8: ...hat a pilot hole is drilled first and its location is checked before proceeding with cutting the hole Clean up the hole edges as necessary removing any sharp edges Ensure the gauge seal is in place ag...

Страница 9: ...ately 80mm of the outer sheathing from the Master gauge loom Remove 8mm of insulation of each core wire Lightly twist the strands of each core and insert into the appropriate connection block position...

Страница 10: ...Exhaust Alert Operating Fitting Instructions 8 HMI 201 01 4 3 Circuit Diagrams Fig 4 Single Engine Single Helm Station Wiring Diagram...

Страница 11: ...Exhaust Alert Operating Fitting Instructions 9 HMI 201 01 Fig 5 Twin Engines Single Helm Station Wiring Diagram...

Страница 12: ...Exhaust Alert Operating Fitting Instructions 10 HMI 201 01 Fig 6 Single Engine Dual Helm Station Wiring Diagram No 120dB siren...

Страница 13: ...Exhaust Alert Operating Fitting Instructions 11 HMI 201 01 Fig 7 Twin Engines Dual Helm Station Wiring Diagram No 120dB siren...

Страница 14: ...en the clamping screws 4 6 Sensor Wiring for Twin Engine Installations Prepare the wiring for both sensors as in the Single Engine instructions above Connect the wires from the Port engine sensor to t...

Страница 15: ...your connections and compare them with the appropriate wiring diagram Switch ON the engine s ignition power supply Both red and green lights should flash momentarily on the Master gauge and the intern...

Страница 16: ...er leaks around the hose connections and the clamps are secure Note any rectification works must only be completed once the engine has been shut down and cooled sufficiently 5 4 Fault Diagnosis Halyar...

Страница 17: ...e sensor with 16 metre cable H021249 AS135 Single engine dual station gauge with through hose sensors with 16 metre cable H021250 AS145 Single engine dual station gauge with removable through hose sen...

Страница 18: ...Exhaust Alert Operating Fitting Instructions 16 HMI 201 01 Installation Notes Installation Date...

Страница 19: ...Exhaust Alert Operating Fitting Instructions 17 HMI 201 01...

Страница 20: ...HMI 201 01 Halyard M I Ltd 86 Cobham Rd Ferndown Ind Estate Wimborne BH21 7PQ T 44 1722 710922 E technical halyard eu com W www halyard eu com...