Halyard Exhaust Alert Mk3 Скачать руководство пользователя страница 15

 

 

Exhaust Alert Operating & Fitting Instructions 

 

13 

HMI 201/01 

4.8

 

Optional 120dB Siren 

 

Identify suitable dry and protected location and securely mount the siren. 

 

Remove approximately 25mm of the outer sheathing from the siren cable(s). 
Extend the cable as required with wiring of the same gauge. 

 

Lightly twist the strands of each inner wire and insert into terminals 7 and 1 
of the connection block and tighten the clamping screws.  

4.9

 

Connecting to a Power Supply 

System -ve connection 

 

The Master gauge requires a common -ve from each engine ignition gauge 
circuit connected to terminal 1 of the connection block. 

ve connection 

 

The  Master  gauge  requires  a  +ve  supply  from  each  engine  ignition  gauge 
circuit connected to terminal 2 only for a single engine and 2 & 3 for a twin 
engine installation. 

Note: Twin engine installations must operate at the same voltage.  Exhaust 
Alert cannot accept a supply from one engine at 12V and the second engine 
at 24V.   

 

Section 5

 

Post Installation Checks 

5.1

 

Electrical Checks 

 

Double-check all your connections and compare them with the  appropriate 
wiring diagram. 

 

Switch ON the engine(s) ignition (power supply).  

 

Both red and green lights should flash momentarily on the Master gauge and 
the internal buzzer sounds. 

 

If fitted the optional 120dB siren also sounds. 

 

Switch OFF the engine(s) ignition (power supply).  

 

Validate  the  system  function  by  unscrewing  the  connecting  plug  on  the 
sensor and remove plug.   

 

Switch  ON  the  relevant  engine  ignition  (power  supply),  for  twin  engine 
installation do one engine at a time.  

 

The  self-test  the  buzzer  should  sound  and  the  relevant  Exhaust  Alert  red 
warning light flash. 

 

Acknowledge  the  alert  (see  Section1.3)  and  switch  OFF  the  engine(s) 
ignition (power supply).  

 

Reconnect  the  sensor  plug  and  tighten  the  screw,  ensuring  the  pins  are 
correctly aligned and the rubber gasket is in place.     

5.2

 

Pre-Engine Start checks 

 

Verify all connections and cable runs are correct and secure.   

WARNING:  

Ensure there is no 
power on the DC 
circuit when the wires 
are being connected. 

NOTE:  

A supply voltage drop 
may cause the 
Exhaust Alert to 
restart and go 
through its self-test 
function.  This may 
occur when there is a 
heavy power draw on 
the batteries such as; 
starting the engine, 
using a bow thruster 
or anchor winch. 

Содержание Exhaust Alert Mk3

Страница 1: ...Exhaust Alert Mk3 Installation Operating Instructions THE SCIENCE OF SILENCE Halyard 2020 All Rights Reserved...

Страница 2: ...the Components 4 3 1 Fitting the sensor 4 3 2 Fitting the Connection Block 5 3 3 Fitting the Master Gauge 5 Section 4 Wiring Connections 7 4 1 Connection Block 7 4 2 Wiring Master Gauge 7 4 3 Circuit...

Страница 3: ...m careless use of hand tools lifting equipment power tools or unaccepted maintenance or working practices Because of the possible danger to persons or property from accidents that may result from the...

Страница 4: ...t system immediately after the engine exhaust outlet The cooling water reduces the temperature of the exhaust system and reduces exhaust noise Should the cooling water flow be blocked or substantially...

Страница 5: ...hs Electrical tie wraps or cable clips to secure the wiring to suitable supports A small electrical screwdriver to fit the terminals on the connection block Spanners to fix the sensors to the flexible...

Страница 6: ...xhaust elbow as detailed in Fig 2 Tidy up the edges of the hole as necessary Identify the correct components from the sensor kit as per Fig 1 Fit rubber grommet G into the centre of one of the large p...

Страница 7: ...fy 12V 24V dc power source Typically this is the ignition circuit of each engine to be monitored but it can be from an independent switch power source Secure the Connection block to a bulkhead or othe...

Страница 8: ...hat a pilot hole is drilled first and its location is checked before proceeding with cutting the hole Clean up the hole edges as necessary removing any sharp edges Ensure the gauge seal is in place ag...

Страница 9: ...ately 80mm of the outer sheathing from the Master gauge loom Remove 8mm of insulation of each core wire Lightly twist the strands of each core and insert into the appropriate connection block position...

Страница 10: ...Exhaust Alert Operating Fitting Instructions 8 HMI 201 01 4 3 Circuit Diagrams Fig 4 Single Engine Single Helm Station Wiring Diagram...

Страница 11: ...Exhaust Alert Operating Fitting Instructions 9 HMI 201 01 Fig 5 Twin Engines Single Helm Station Wiring Diagram...

Страница 12: ...Exhaust Alert Operating Fitting Instructions 10 HMI 201 01 Fig 6 Single Engine Dual Helm Station Wiring Diagram No 120dB siren...

Страница 13: ...Exhaust Alert Operating Fitting Instructions 11 HMI 201 01 Fig 7 Twin Engines Dual Helm Station Wiring Diagram No 120dB siren...

Страница 14: ...en the clamping screws 4 6 Sensor Wiring for Twin Engine Installations Prepare the wiring for both sensors as in the Single Engine instructions above Connect the wires from the Port engine sensor to t...

Страница 15: ...your connections and compare them with the appropriate wiring diagram Switch ON the engine s ignition power supply Both red and green lights should flash momentarily on the Master gauge and the intern...

Страница 16: ...er leaks around the hose connections and the clamps are secure Note any rectification works must only be completed once the engine has been shut down and cooled sufficiently 5 4 Fault Diagnosis Halyar...

Страница 17: ...e sensor with 16 metre cable H021249 AS135 Single engine dual station gauge with through hose sensors with 16 metre cable H021250 AS145 Single engine dual station gauge with removable through hose sen...

Страница 18: ...Exhaust Alert Operating Fitting Instructions 16 HMI 201 01 Installation Notes Installation Date...

Страница 19: ...Exhaust Alert Operating Fitting Instructions 17 HMI 201 01...

Страница 20: ...HMI 201 01 Halyard M I Ltd 86 Cobham Rd Ferndown Ind Estate Wimborne BH21 7PQ T 44 1722 710922 E technical halyard eu com W www halyard eu com...

Отзывы: