background image

halveon sagl

via Valdani 1 • CH-6830 Chiasso (Switzerland

[email protected] • www.halveon.ch

MU

OPERATING

INSTRUCTIONS

VI-

 

DEVICE EXAMINATIONS 

 

“T•Stream Software” has an innovative inspecting function that 

effectively ensures the safe usage the Software icon to enter and then 

connect the device to your computer, the software will automatically 

examine the device including battery power, hardware, and connection 

status.

Red light means error; green light means OK to start the configuration.  

VI-

 

DEVICE CONFIGURATION 

Device information area 

, each unit has a unique serial number, and 

manually started by pressing the button.

(if delay is not needed, select 0 min)

 

: after the delay period passed, the device will start recording 

: the logger will auto-start at the given time.

: the logger will auto-start recording once it meets the 

selected range.

Select a temperature and humidity range, alarm type and delay time 

for the alarm settings.

VI-

 

OTHER FUNCTIONS 

Type any information in area 5, the info will be presented on the 

generated reports. The info could be: customer, location, order 

number, etc. 

 

 

After selected, user cannot stop the device  

manually only by connecting the device to a PC and  

After selected, user doesn’t need to config the device each time. To restart 

follow the same starting procedure.

Note: the orginal data will be formatted once restart, please acquire 

the reports before restarting.

 

When user needs to config many units at one time, for time

efficiency, select the required configuration, and then choose “Auto 

Config”, the software will config the units automatically: just plug in 

and out, with no need for further procedures.

VII

  TECHNICAL SPECIFICATION

MODEL

T•Stream MU

TYPE

Multi-use

SENSOR

NTC

RANGE

ACCURACY

RESOLUTION

0,1

CAPACITY

BATTERY

3.6v Li

BATTERY LIFE

2-3 years or longer

CALIBRATION

Factory Calibration and NIST CNAS

CERTIFICATION

WARRANTY

1 year

SIZE

106x51x18mm

WEIGHT 

65g

WATER-PROOF

IP54

CONNECTION

USB 2.0

SOFTWARE

T•Stream Software

VIII

 

IMPORTANT NOTES

USAGE

regulations.

BATTERY

tempeartures, this could lead to destruction of the battery and may cause 

While the reports are generating, please do not remove the logger.

To ensure long-term effectiveness, store the logger at room temperature 

before using.

The logger’s shelf life may be shortened if it is stored outside of the 

temperature range.

injuries.

SECURITY NOTE

LIABILITY

The manufacturer shall not be held liable:

a.   If the device was used beyond the manufacturer’s given limitations

b.   For any claims due to the imporper storage and use of the deivce

c.   For any problems with the cooling unit

d.   If the stored goods have expired

e.   For incorrect readings of the device or if it was activated with a low battery 

ATTENTION: the 

T•Stream MU 

loggers monitor temperature and humidity 

exposure and not the product quality. It’s purpose is to send a signal if product 

quality evaluation/testing is required.  

 

 

HI

Temp & Humidity Alarm

 is not when temperature exceeds theselected 

range will alert in the way of sounding, but to indicates on the LCD 

screen and the reports. If no need then un-select the function then 

HI

:  

Sometimes due to an aging of PC USB port, or not connect USB port 

entirely will lead to a missing. If this happens, please double check  

the PC USB port or try another port.

user can configure the device to their preference.

after configured successfully, the device needs to be

this is a safety hazard!

Do not use in microwaves, there is a risk of explosion.

X-ray exposure can damage the logger. 

Отзывы: