Halton EcoloAir 10000CFM Скачать руководство пользователя страница 6

HALTON LIMITED WARRANTY

Halton  (“Manufacturer”). Warrants  only  to  its  direct  purchasers  and  to  no  others,  that  all  products 
manufactured by the Manufacturer shall be free from defect in materials and workmanship for a period 
of twelve (12) months from the date of the original installation and start-up or eighteen (18) months 
from date of shipment, whichever occurs first. All products sold but not manufactured by Manufacturer 
will be warranted for a period of twelve (12) months from date of shipment. 

For products manufactured by the Manufacturer we agree to pay any reasonable labor costs necessary 
to repair or replace, at Manufacturers option, defective parts or materials for a period of twelve (12) 
months from date of original installation and start-up or eighteen (18) months from date of shipment, 
whichever occurs first. All labor costs subject hereto shall be performed during standard work hours at 
straight-time rates. 

For products sold but not manufactured by the Manufacturer we agree to pay any reasonable labor costs 
necessary to repair or replace, at Manufacturers option, defective parts or materials for a period of (90) 
days from date of original installation and start-up or (12) months from date of shipment, whichever 
occurs first. All labor costs subject hereto shall be performed during standard work hours at straight-
time rates. 

Purchaser  shall  pay  incurred  premium  labor  charge,  including  overtime,  weekends  and  holidays. 
Travel time, service charges, miscellaneous tools, material charges, and labor charges resulting from 
inaccessibility of equipment will not be paid by Manufacturer. 

This 

LIMITED WARRANTY SHALL APPLY ONLY

 to products that have been installed and maintained 

in accordance with the installation and Care Instruction Manuals. Purchaser shall be solely responsible 
for adhering to the instructions and procedures set forth in the said instruction manuals. 

This 

LIMITED WARRANTY SHALL NOT BE APPLICABLE

 to any damage or defect resulting from fire, 

flood, freezing or any Act of God, abuse, misuse, accident, neglect or failure to adhere to all instructions 
set forth in the installation and Care Instruction Manuals. Furthermore, this limited warranty shall not 
apply to any product that has been altered, unless such alteration has been approved in writing by a 
duly authorized representative of the manufacturer. In no event shall the manufacturer be liable for any 
loss, expense,  personal injury or consequential damage, of any kind or character, as may result from a 
defect in material, and/or workmanship, however caused. 

EXCEPT AS IS EXPRESSLY SET FORTH IN THIS LIMITED WARRANTY, MANUFACTURER MAKES 
NO WARRANTY OF MARKETABILITY FOR FITNESS OR ANY PARTICULAR PURPOSE. NEITHER 
DOES MANUFACTURER MAKE ANY WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO 
PRODUCTS SOLD BY MANUFACTURER OR AS TO THE USE THEREOF. 

Halton Indoor Climate Systems, Ltd.

1021 Brevik Place, Mississauga, ON L4W 3R7 CANADA

Tel: 905-624-0301 Fax:  905-624-5547

Website address  

www.haltoncanada.com

Halton Company

101 Industrial Drive, Scottsville, 42164 USA

Tel: 270-237-5600 Fax:  270-237-5700

Website address  

www.haltoncompany.com

Содержание EcoloAir 10000CFM

Страница 1: ...URE ELECTRICAL SUPPLY CONFORMS WITH ELECTRICAL CHARACTERISTICS SHOWN ON THE RATING PLATE AND N E C REQUIREMENTS THE INSTALLATION OF THE HOOD AND DUCT WORK LEADING TO AND EXITING THE ECOLOAIR SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 96 AND LOCAL CODES UL 1978 Standard for Grease Ducts UL 710 Exhaust Hoods for Commercial Cooking Equipment ULC S647 05 and or UL197 ...

Страница 2: ... DETAIL LOCATED TOP OF FILTER OUTLET IF AN INLET B FAN TOP INSULATION LINING OPTION FOR EXTERIOR ICN INTERIOR FAN TOP PANEL BOTTOM FLOOR PANEL WITH TURNED UP FLANGE AT FAN INLET INTERIOR FLOOR CONNECTION FLANGE FILTER OUTLET 4 STRUCTURAL FLOOR BASE PLAN VIEW INLET PANEL CONNECTION FLANGE ACCESS SIDE INLET GASKET PROVIDED BY FACTORY FAN BOTTOM PANEL TURNED UP FLANGE FAN TOP PANEL LESS INSULATION FI...

Страница 3: ...CT CONNECTIONS 1 The exhaust duct connection at the inlet entrance to the EcoloAir system must be continuously welded all around See figure 2 2 The duct must be transitioned to the full opening of the filter module inlet 3 All fan outlet openings to which ducts are attached will be provided with discharge collars See figure 3 4 All openings are to be transitioned to the duct size 5 For filter modu...

Страница 4: ... the filters be properly seated against the support mullion as shown in figure 4 and 5 ECOLOAIR UNIT FILTER SUPPORTING FRAME PRE FILTER MERV 7 AIR FLOW EXHAUST FILTER INLET MEDIUM FILTER MERV 14 FIGURE 4 FILTER AIR SEAL GASKETING CLAMP HANDLE TAPED TO SIDE OF FILTER FOR SHIPPING ABSOLUTE FILTER MERV 16 FILTER CLAMP PULL OUT TO LOOSEN FILTER PUSH IN TO TIGHTEN FILTER AGAINST AIR SEAL CENTRE MULLION...

Страница 5: ...d installed SCHEMATIC WIRING DIAGRAMS For field wiring diagrams and field connections refer to Halton s shop drawings shipped with unit or contact factory Additional copies of shop drawings are available on request FAN SECTION Important note Before starting the fan unit remove fan isolator hold down brackets The brackets are used for shipping purposes only When the brackets are removed the fan sho...

Страница 6: ...ce charges miscellaneous tools material charges and labor charges resulting from inaccessibility of equipment will not be paid by Manufacturer This LIMITED WARRANTY SHALL APPLY ONLY to products that have been installed and maintained in accordance with the installation and Care Instruction Manuals Purchaser shall be solely responsible for adhering to the instructions and procedures set forth in th...

Отзывы: