background image

17

Digital Pulsed Outputs (DPO)

Digital Pulsed Outputs are capable of producing 
pulsed waveforms with varying duty and 
frequency. 
When a Digital Pulsed Output is activated by the 
ECU the output will switch to ground.
The pull-up voltage specifies the waveforms 
maximum voltage output eg 0 to 12V or 0 to 5V.
DPOs can be used to control various low-current 
devices such as shift lights, bypass air control 
valves, boost control solenoids, tachometers etc.

Specs:

• Individual software-selectable 12V or 5V  
   4k7 pull-up

• Flyback protected

• Capable of switching 3A to ground

• 10kHz switching speed

• Automatic overcurrent protection

• 0 to 27V voltage feedback

Half Bridge Outputs (HBO)

Half Bridge Outputs are push-pull pulse width 
modulated (PWM) outputs. If not being used as 
push-pull drivers, Half Bridge Outputs can be 
used as generic high/low PWM outputs capable 
of sinking 8A to ground and driving 8A to 12V at 
2.2kHz.

HBOs can be used to control any push-pull type 
device such as DBW throttle motors (max of 2 
wired separately) and stepper motors.
When used as generic high/low switched or 
PWM outputs, Half Bridge Outputs can be used 
as generic low-side DPOs or to control devices 
such as high-side driven solenoids (e.g. VTEC 
Solenoids), high side switched automatic 
transmission solenoids etc.

Specs:

 

• Capable of sinking 8A to ground and 
   driving 8A to 12V 
• Automatic Overcurrent and  
   Overtemperature Protection 
• 0 to 27V voltage feedback 
• High side current feedback 
• 18kHz switching speed in DBW mode 
• Capable of 0-100% duty cycle

NEXUS R5 WIRING

DPO

HCO

BOOST

CONTROL

SOLENOID

TO OTHER

DEVICES

HBO 1

HBO 4

HBO 2

HBO 3

DBW THROTTLE 2

DBW THROTTLE 1

Example wiring connection

Example wiring connection

Ensure the High Current Output (8A or 25A) 
used to power solenoids and other devices is 
capable of supplying the required current.

Injection Outputs

All Injectors are to be wired directly to the ECU’s 
corresponding cylinder output pins. 
When an injection event occurs the ECU will 
ground the output pin, opening the injector.
All injectors must be wired to a 12V 
supply from one of the High Current Outputs on 
the NEXUS R5.
When not used for injection, pins can be used as 
generic Digital Pulsed Outputs (DPO) capable of 
switching 2A to ground.

Specs:

• Current controlled output
• 8A Peak, 2A Hold
• 0 to 55V voltage feedback

INJ #1

INJ #4

INJ #2

INJ #3

INJ #5

INJ #8

INJ #6

INJ #7

HCO

WIRING SHOWN

SEQUENTIAL INJECTION

Example wiring connection 
(Sequential Injection wiring shown)

Ensure the High Current Output (8A or 25A) used to 
power the injectors is capable of supplying the required 
current.

16

Содержание NEXUS R5

Страница 1: ...1 QUICK START GUIDE...

Страница 2: ...and Pins Set Male DTP06 4S Black connector 25A inc male plug female pins wedgelock seal HT 031201 Plug Set SurLok connectors red black 200A HT 030030 1AWG Battery Cable red black pair Pre terminated...

Страница 3: ...operation on main power or low power mode Blue Connect to unit and install firmware Red Hardware fault DTC None DTCs not present Yellow A DTC is present of any kind past present not severe severe Blue...

Страница 4: ...nnels per log 300 DIMENSIONS Enclosure Not including connector protrusion 257 x 132 x 51 mm 10 1 x 5 2 x 2 in Overall Including connector protrusion 257 x 163 x 61 mm 10 1 x 6 4 x 2 4 in Weight 1 50 k...

Страница 5: ...ely inactive To set up your Wi Fi connection follow these steps 1 Open NSP and connect to your NEXUS R5 via the supplied USB C cable 2 Click on Connections in the feature tree and enable the Wi Fi mod...

Страница 6: ...input and power up the ECU Method 2 instead of using the power for ignition switch pin the hot side of the ignition switch can simply be wired to any constant 12V source such that a 12V signal is dete...

Страница 7: ...MOUNTING TEMPLATE MOUNTING TEMPLATE...

Страница 8: ...ECU to an ignition module before setting the ignition firing edge correctly may damage the module and coils therefore it is advised to disconnect the module or disable the power to the ignition system...

Страница 9: ...ide driven solenoids e g VTEC Solenoids high side switched automatic transmission solenoids etc Specs Capable of sinking 8A to ground and driving 8A to 12V Automatic Overcurrent and Overtemperature Pr...

Страница 10: ...gger and Cam Home Inputs The crank and cam position sensors are required so that the ECU has the necessary information available to determine engine speed and position at any point in time Generally t...

Страница 11: ...hstand Example Wiring Connections Example Wiring Connections Analogue Voltage Inputs AVI Analogue Voltage Inputs are inputs to the ECU that accept variable voltage signals from 0V to 5V such as signal...

Страница 12: ...hicle Avoid sparks open flames or use of electrical devices near flammable substances Do not run the engine with a battery charger connected as this could damage the ECU and other electrical equipment...

Страница 13: ...ail usa haltech com Haltech USA West Race Winning Brands 10800 Valley View Street Cypress CA 90630 USA Phone 1 888 298 8116 Email usa haltech com Haltech Europe Ottogasse 2A 2333 Leopoldsdorf Austria...

Отзывы: