3.2 Connections for Four-Wire version (standard) in the device:
One measurement range
Four measurement ranges
Note the prescribed supply voltage (see rating plate). Also follow the
connection diagram on the appliance cover / circuit board mount.
The transducer outputs are protected from short circuits. The DC-supplied appliances are
protected from reverse polarity of the supply voltage.
ST4 Pin
Connection name Meaning
1
24V
Power supply input - 24VAC/DC
2
GND
Ground for power supply
3
OUT
Voltage or current output
4
GND
Ground for output signal
5
SET 0
Zero-point input (+24V zero-point is active)