Instruction manual PS11/PK11 

Safety precautions 

1.1 Appropriate use 

In addition to differential pressure data, the PS11/PK11 differential pressure 
transducer also records positive and negative overpressures. 
 
Always observe the operating requirements

—particularly the permissible supply 

voltage

—indicated on the rating plate and in the ”Technical data” section of this 

manual. 
 
The instrument may only be handled as indicated in this manual. Modifications to the 
instrument are prohibited. The manufacturer is not liable for damages caused by 
improper use or failure to follow these instructions. Violations of this type render all 
warranty claims null and void. 
 
 

1.2 Shipping, assembly, electrical connections and start-up 

Do not close the pressure inlets during shipping. Changes in barometric pressure 
may damage devices with low measuring ranges. 
 
Assembly and the electrical connections should only be handled by professionals. 
They should be given proper training and be authorised by the operator of the facility. 
 
The instrument may only be operated by appropriately trained individuals who have 
been authorized by the operator of the facility. 
 
Do not carry out a function test with compressed or breathable air. This would 
damage instruments with low measuring ranges. 
 
Measurement errors may occur if the instrument is not kept protected from sunlight. 
 
Specific safety precautions are given in individual sections of this manual. 
 
 

1.3 Troubleshooting, maintenance, repairs, disposal 

The individual responsible for the electrical connections must be notified immediately 
if the instrument is damaged or if errors occur that cannot be corrected as indicated in 
section 6. 
 
This individual must take the instrument out of service until the error has been 
corrected and ensure that it cannot be used unintentionally. 
 

Always unplug the supply voltage

 

before opening the instrument! 

 
This instrument requires no maintenance. 

 

Only the manufacturer may perform repairs that require the housing to be opened. 
 
The electronic components of the instrument contain environmentally hazardous 
materials and materials that can be reused. The instrument must therefore be sent to 

Содержание PK11

Страница 1: ...l Mounting Type PS11 Type PK11 with Contact Point halstrup walcher GmbH Stegener Stra e 10 D 79199 Kirchzarten Phone 49 0 76 61 39 63 0 Fax 49 0 76 61 39 63 99 E mail info halstrup walcher com Interne...

Страница 2: ...ctions and start up 4 1 3 Troubleshooting maintenance repairs disposal 4 1 4 Symbols 5 2 Instrument description 6 3 Start up 6 3 1 Features 6 3 2 Supply voltage connections in the instrument 7 4 Calib...

Страница 3: ...ly available throughout the lifecycle of the instrument It must be provided to any individuals who assume responsibility for operating the instrument at a later date It must include any supplementary...

Страница 4: ...ised by the operator of the facility The instrument may only be operated by appropriately trained individuals who have been authorized by the operator of the facility Do not carry out a function test...

Страница 5: ...r operation could result in the following hazards WARNING This warns you of a potential hazard that could lead to bodily injury up to and including death if the corresponding instructions are not foll...

Страница 6: ...ictional parts or parts subject to mechanical wear 3 Start up 3 1 Features Although the PS11 PK11 pressure transducer is highly robust it is nevertheless a precision instrument and should be handled w...

Страница 7: ...uments are calibrated by the manufacturer before delivery During assembly it should only be necessary to correct any positional errors However the following tools are required if calibration is still...

Страница 8: ...point with the NO contact function The same instructions apply to setting the NC contact function only the function is inverted You can access the P6 potentiometer through a bore in the front of the i...

Страница 9: ...defective pressure measurement cell send the instrument to the manufacturer for repair 7 Technical data Measurement data measurement ranges 300 Pa to 200 kPa overload capacity 10 x the final value of...

Страница 10: ...an be adjusted over the complete measurement range using the potentiometer Physical data pressure port FESTO elbow AN quick connector for PVC tubing external 6mm electrical connection screw terminals...

Страница 11: ...ion drawings 111 45 U OUT 20 I OUT 19 5 UB GND GND 31 25 73 111 Verschlu stopfen f r Schlauch au en 6 2x L Steckverschraubung 7100 003754B_PS11_PK11_eng doc 02 11 2021 Ze cover seal FESTO elbow AN qui...

Отзывы: