Instruction manual PS11/PK11
10
Electrical data
power consumption
max. 1.4 W
supply voltage
24 VDC +20% / -15%
(smoothed, permissible peak-to-valley ratio = 1000
mV)
load resistance R
L
R
L
2 k
at output voltage 0...10 V
effect of change from the minimal resistance
to
∞
: max. 0.2 %
working resistance
R
B
R
B
=
500
effect of change from 500 Ω to 0 Ω: max. 0.2%
output signal
0 to 10 V and 4 to 20 mA
(voltage limited to 10 V)
contact points
single-pole switching relay
max. load capability 230 VAC, 5 A
can be adjusted over the complete measurement range
using the potentiometer
Physical data
pressure port
FESTO elbow (AN) quick connector for PVC tubing
(external Ø 6mm)
electrical connection
screw terminals for cables up to 2.5 mm
2
mounting orientation
mounted vertically on 35mm DIN top hat rails
dimensions (w x l x h)
45 x 111 x 73 mm
protection class
IP40
weight
0.25 kg
Appendix A: Parts in contact with measurement medium
Beryllium bronze CuBe2
Araldite CY236 / HY988
Mu metal (nickel alloy)
Loctite 242e
Brass CuZn39Pb3
Carbonyl iron
Aluminium AlCuMgPb / AlMg3
KEL (FPM: fluorinated rubber)
Silicon (tubing), optional: Viton
Vepuran Vu 4457/51
Crastin (PTBP)
UHU-Plus endfest 300 binder