background image

98341C (11/06)

WM14WQ*1P

PAGE 4

ITEMIZED PARTS LIST

ITEM NO.

PART NO.

DESCRIPTION

51544C

102639931640
160270508640

28340C
75561C
66506C
31513C
36250C
36254C
36255C
36189C
45696C

601418151550
101453431640
101507531550

75494C
55860C
40136C
66203C
66767C
36208C
15005C
26860C
26861C
26862C
50986C
61314C
55996C
45670C
75588C
55913C
56159C
70682C

See Color Table
See Color Table

56092C
70683C

See Color Table

75589C

400660943730

Bubbler
Drain Plug
Strainer Plate
Basin
Fitting-Elbow 3/8 x 3/8 NPT x 90
Evaporator
Cold Control
Compressor Serv. Pak
Overload
Relay
Relay Cover
Tailpipe Assy
Condenser
Cap Push Button
Push Button Stem
Check Valve
Regulator Bracket
Water Temperature Valve
Drier
Heat Exchanger
Power Cord
Regulator Retaining Nut
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Regulator Holder
Regulator
Strainer
Vacuum Break
Nut - Slip Joint 1-1/4
Adaptor - Drain
Nipple - Bubbler
Tee - 1/4
Side Panel - Right
Side Panel - Left
Poly Tubing (Cut To Length)
Union - 1/4
Front Panel
Gasket
Hanger Bracket

1
2
3
4
5
6
7

8*

9

10

11

12**

13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39

-

*INCLUDES RELAY & OVERLOAD.  IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE:  All correspondence pertaining to any of the above water coolers or
orders for repair parts MUST include Model No. and Serial No. of cooler, name
and part number of replacement part.

2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500

PRINTED IN U.S.A.

CONDENSER WATER VALVE ADJUSTMENT

The condenser water valve is factory preset for a condenser water
outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate
at the valve using the following procedures.

1.

  START UP COMPRESSOR

    

This can be accomplished by depressing the cooler push button

     (See Fig. 1 - Item 14).  Keep water running during the entire
     readjustment procedure.

2.  

ADJUSTMENT CONDENSER WATER VALVE

    Adjust valve by rotating adjustment stem.  Rotating stem clockwise will
   decrease water flow. Counterclockwise rotation will increase water
   flow.  Increasing water flow will result in a lower condenser outlet
   temperature, while decreasing water flow will result in a higher outlet
   temperature.  Proper adjustment is attained when condenser outlet
    temperature is 95° to 105° F.

WIRING DIAGRAM

This drawing is merely for illustrating the

components of the electrical system.

FIG. 6

COLOR

ITEM  35

Platinum (PV)
Stainless Steel (SS)

401432248410
401432242830

ITEM  38

401483948410
401483942830

ITEM  34

401484048410
401484042830

**Includes items 30, 31 & 39

REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

FAN

10

12

M

13

C

S

2

GND

COLD CONTROL

(WATER)

WHT

BLK

11

3

1

14

OVERLOAD

COMPRESSOR

RELAY

Отзывы: