SCWT14A-WC-Q*1D

PAGE 4

97321C (7/98)

ITEM NO.

PART NO.

DESCRIPTION

15005C

51544C

10-15075-31-550

10-14534-31-640

10-26399-31-640

16-02705-08-640

17-14037-42-590

26860C

26861C

26862C

31513C

35762C

31027C

35766C

19-42439-01-550

19-26684-51-550

45688C

66229C

40136C

50986C

60-14181-51-550

66506C

55880C

61314C

66202C

75494C

55996C

55913C

55885C

15008C

70682C

See Color Table

See Color Table

See Color Table

Nut-Regulator Retaining

Bubbler

Push Button Stem

Cap Push Button

Drain Plug

Strainer Plate

Basin

Regulator Lever

Pivot Bracket

Regulator Retaining Bracket

Cold Control

Compressor Service Pak

Overload/Relay Assy

Relay Cover

Electrical Shield

Power Cord

Precooler

Heat Exchanger

Water Temperature Valve

Regulator Holder

Condenser Assy

Evaporator

Regulator Mounting Bracket

Regulator

Drier

Check Valve

Strainer

Adaptor-Drain W/O Holes

Nut 1-1/4 Slip Joint

Nipple - Bubbler

Tee - 1/4

Side Panel - Right

Side Panel - Left

Front Panel

Platinum (PV)

Almond (AV)

Slate (SV)

Stnlss Stl (SS)

401536248410

26912C

401536248440

401536242830

401536348410

26908C

401536348440

401536342830

401507448410

26904C

401507448440

401507442830

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

2222 CAMDEN COURT

OAK BROOK, IL 60523

630.574.3500

PRINTED IN U.S.A.

RIGHT PANEL

FRONT PANEL

COLOR

LEFT PANEL

*INCLUDES RELAY & OVERLOAD.  IF UNDER WARRANTY, REPLACE

WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE:  All correspondence pertaining to any of the above water coolers or

orders for repair parts MUST include Model No. and Serial No. of cooler,

name and part number of replacement part.

ITEMIZED PARTS LIST

1

2

3

4

5

6

7

8

9

10

11

12*

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

NS

FIG. 6

CONDENSER WATER VALVE ADJUSTMENT

The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F.

If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.

1.

START UP COMPRESSOR

      This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 4).  Keep water

       running during the entire readjustment procedure.

2.  

ADJUSTMENT CONDENSER WATER VALVE

       Adjust valve by rotating adjustment stem.  Rotating stem clockwise will decrease water flow.

      Counterclockwise rotation will increase water flow.  Increasing water flow will result in a lower

      condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature.

       Proper adjustment is attained when condenser outlet temperature is 95° to 105° F.

WIRING DIAGRAM

This drawing is merely for illustrating the

components of the electrical system.