background image

Page 3

1000003018 (Rev. D - 09/18)

HTHBHVR8_2A    HTHBHVR8-NF_2A

2-

7/

16

"

63

m

m

3-

1/

2"

89

m

m

4-

1/

2"

11

4m

m

5" 12

7m

m

10

"

25

4m

m

13

-7

/8

"

35

2m

m

2-

1/

2"

63

m

m

11

/1

6"

18

m

m

4-

9/

16

"

11

6m

m

2-

9/

16

"

65

m

m

7-

1/

4"

18

5m

m

18

-3

/8

"

46

7m

m

21

-3

/8

"

54

3m

m

25

"

63

5m

m

F

A

D

B

E

E

31

"

78

8m

m

49

-1

/2

"

12

57

m

m

18

-1

/2

"

47

0m

m

FI

NI

SH

ED

 F

LO

O

R

12

-5

/1

6"

31

2m

m

6-

3/

4"

17

1m

m

6-

1/

4"

15

9m

m

1-

1/

2"

38

m

m

2-

5/

8"

66

m

m

8" 20

3m

m

C

27

"

68

6m

m

*

31

-1

5/

16

"

81

1m

m

RI

M

 H

EI

G

HT

33

-1

/1

6"

84

0m

m

O

RI

FI

CE

HE

I

G

HT

18

-9

/1

6"

47

2m

m

51

-1

/8

"

12

98

m

m

5-

1/

8"

13

1m

m

48

"

12

19

m

m

O

5/

16

"

8m

m

M

O

UN

TI

N

G

HO

LE

(3

 P

L)

1/

4"

 X

 1

/2

" (

6m

m

 X

 1

3m

m

)

O

BR

O

UN

HO

LE

 (5

 P

L)

HA

N

G

ER

 B

RA

C

K

ET

7" 17

8m

m

7" 17

8m

m

16

-5

/1

6"

41

4m

m

1-

1/

4"

32

m

m

1-

1/

4"

32

m

m

HTHBHVR8 

ROUGH

-IN

REDUCE HEIGHT BY

 3” FOR INST

ALLA

TION OF

 CHILDREN’S 

ADA

 COOLER

LEGEND: A = W

ater Mains Supply

, 3/8” (9.5mm) O.D. compression outlet of Shut-off V

alve (not provided) to be 1-1/2” (38mm) from W

all. 

B = W

aste Outlet, 1-1/4” (31.8mm) O.D. Drain 

Tube

C = 1-1/4” (31.8mm) 

Trap (not provided). 

D = Electrical Mains Supply Duplex Outled, 3-wire in Recessed Box.  Must have Ground Fault Circuit Interrupter (GFCI) protection. E = Ensure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. 

F = 7/16” (1

1mm) Bolt holes for fastening unit to wall.

Содержание HydroBoost HTHBHVR8-25

Страница 1: ...er installation keep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have...

Страница 2: ...upported securely Add fixture support carrier if wall will not provide adequate support 2 Install water cooler onto wall bracket and secure to wall Installation Water Line connection 1 Ensure Mains Wa...

Страница 3: ...m MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm HTHBHVR8 ROUGH IN REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA...

Страница 4: ...Bottle Filler Do not plug into electrical outlet 7 With the power cord waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin NOTE...

Страница 5: ...how FLTR 0 The Green LED should be illuminated indicating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR WHERE APPLICABLE Depress the program button for approximately 2 s...

Страница 6: ...ses o Protective gloves o Hex drives Service Adjustments 1 Temperature Control Factory set for 50 F 5 10 C 5 water under normal conditions To adjust water temperature turn screw clockwise for colder c...

Страница 7: ...ilter Head Mounting Bracket John Guest Fittings Screws For Replacement Parts contact your local distributor or visit our website www HalseyTaylor com 2 Bottle Filler Removal Loosen but DO NOT remove t...

Отзывы: