background image

HTHBHACG8BL*1B     HTHBHACG8BLNF*1B

1000001716  (Rev. M - 01/19)

Page 3

Fig. 2

REDUCE HEIGHT BY

 3" FOR INST

ALLA

TION OF CHILDREN'S 

ADA

 COOLER

STANDARD TWO-LEVEL INSTALLATION

LEGEND

/LEYENDA

/LÉGENDE

= RECOMMENDED

 W

ATER

 SUPPL

Y LOCA

TION

 3

/8

 O

.D

. UNPLA

TED

 COPPER

 TUBE

 CONNECT

 STUB

 WITH

 SHUT

 OFF

 (BY

 OTHERS

) 3

 IN

. (

76

mm

MAXIMUM

 OUT

 FROM

 W

ALL

 

  La UBICACION 3/8 O RECOMENDADA

 de 

ABASTECIMIENT

O DE 

AGUA. D. El 

TUBO del COBRE de UNPLA

TED CONECT

TALONARIO CON 

AP

AGO 

(POR OTROS) 3 en. (76 Mm) el MAXIMO FUERA

 DE P

ARED

        

L’O.D de 3/8 d’EMPLACEMENT

 DE PROVISION D’EAU RECOMMANDE. LE 

TUBE DE CUIVRE DE UNPLA

TED CONNECTE STUB 

AVEC ETEINT

 (P

AR 

LES 

AUTRES) 3 dans. (76 mm) le MAXIMUM HORS DU MUR

B

 =

 RECOMMENDED

 LOCA

TION

 FOR

 W

ASTE

 OUTLET

 1

-1

/2

” 

O

.D

.  

DRAIN

 STUB

 2

 IN

. OUT

 FROM

 W

ALL

 UBICACIÓN

 RECOMENDADA

 P

ARA

 EL

 DRENAJE

 DE

 SALIDA

 DE

 AGUA

, DE

 1

-1

/2

” DE

 DIÁMETRO

. El 

TALONARIO 2 FUERA

 DE P

ARED

EMPLACEMENT

 RECOMMANDÉ

 POUR

 LE

 DRAIN

 DE

 D

.E

. 1

-1

/2

” DE

 SOR

TIE

 D

’EAU

. STUB 2 HORS DU MUR

C

 =

 1

-1

/2

” 

TRAP

 NOT

 FURNISHED

PURGADOR

 DE

 1

-1

/2

” NO

 PROPORCIONADO

SIPHON

 1

-1

/2

” NON

 FOURNI

LEGEND

/LEYENDA

/LÉGENDE

D

 =

 ELECTRICAL

 SUPPL

(3

) WIRE

 RECESSED

 BOX

 DUPLEX

 OUTLET

**

SUMINISTRO

 ELÉCTRICO

 (3

) CAJA

 ENCHUFE

 DE

 ALAMBRE

 SALIDA

 DÚPLEX

ALIMENT

ATION

 ÉLECTRIQUE

 (3

) BOÎTIER

 ENCASTRÉ

INSURE

 PROPER

 VENTILA

TION

 BY

 MAINT

AINING

 6

” 

(1

52

 mm

) (

MIN

.) 

CLEARANCE

 FROM

 CABINET

 LOUVERS

 T

O

 W

ALL

.

ASEGURE

 UNA

 VENTILACIÓN

 ADECUADA

 MANTENIENDO

 UN

 ESP

ACIO

 E

 6

” (

15

mm

) (

MÍN

.) 

DE

 HOLGURA

 ENTRE

 LA

 REJILLA

DE

 VENTILACIÓN

 DEL

 MUEBLE

 Y

 LA

 P

ARED

.

ASSUREZ

-VOUS

 UNE

 BONNE

 VENTILA

TION

 EN

 GARDANT

 6

” (

15

mm

) (

MIN

.) 

ENTRE

 LES

 ÉVENTS

 DE

 L

’ENCEINTE

 ET

 LE

 MUR

.

7/

16

 BOL

HOLES

 FOR

 F

ASTENING

 UNIT

 T

O

 W

ALL

AGUJEROS

 DE

 LAS

 TUERCAS

 DE

 7

/1

PARA

 SUJET

AR

 LA

 UNIDAD

 A

 LA

 P

ARED

TROUS

 D

’ÉCROUS

 7

/1

POUR

 FIXER

 L

’APP

AREIL

 AU

 MUR

**

NEW

 INST

ALLA

TIONS

 MUST

 USE

 GROUND

 F

AUL

CIRCUIT

 INTERRUPTER

 (GFCI

)

**

Las nuevas instalaciones deben utilizar el interruptor de circuito de tierra de la avería (GFCI)

**

Les nouvelles installations doivent employer l’interrupteur de circuit moulu de défaut (GFCI)

12

 5

/16

"

313

m

m

1/2

"

89

m

m

18

 3

/4

"

476

m

m

1/4

"

159

m

m

20

 1

/8

"

51

1m

m

20

 3

/8

"

518

m

m

7/

16

"

63

m

m

5"

127

m

m

10"

254m

m

A

D

E

F

B

FIN

IS

HED

 F

LOOR

HAN

GER

 B

RAC

KET

13

 7

/8

"

352m

m

37

 1

/2

"

95

2mm

1 3

/8

"

35

mm

1 3

/8

"

35

mm

3/

4"

146

m

m

3/

4"

146

m

m

1 3

/8

"

35

m

m

1 3

/8

"

35

mm

3/

4"

146

m

m

3/

4"

146

m

m

1/2

"

165

m

m

18

 1

/16

"

459

m

m

11

/16

"

18

mm

9/

16

"

11

6mm

9/

16

"

65

m

m

1/4

"

185

m

m

E

F

5/

16

" (8

m

m)

 D

IA.

(10

 H

OLE

S)

LC

LC

27

"

686

m

m

ADA

 

REQU

RI

EMEN

TS*

C

1/8

"

105

m

m

3/

4"

172

m

m

8"

203

m

m

7"

178

m

m

7"

178

m

m

17

 7

/8

"

454

m

m

O

7/

16

"

11m

m

MOUNT

IN

HOL

ES

(6)

58

 9

/16

"

148

8m

m

15"

381

m

m

9/

16

"

90

mm

18

 7

/8

"

479

m

m

31

 15

/16

"

81

1mm

RI

M H

EIG

HT

18

 5

/8

"

472

m

m

33"

838

m

m

OR

IF

IC

HE

IG

HT

39

 7

/16

"

100

2m

m

OR

IF

IC

HE

IG

HT

5/

8"

67

mm

ACT

IVAT

IO

N

  S

ENSO

R

45

 9

/16

"

1157

m

m

25

 1

/8

"

638

m

m

1/2

"

11

4m

m

Содержание HydroBoost HTHBHACG8BL 1B Series

Страница 1: ...ge 1 MANUAL DEL PROPIETARIO HALSEY TAYLOR MANUEL DE L UTILISATION HALSEY TAYLOR Hydroboost Bottle Filling Station and Cooler Owners Manual Estaci n de llenado de botella Hydroboost y enfriador Station...

Страница 2: ...pour ie Mechanisme de Barre poussoir 25 2 17 40 19 23 19 19 3 7 12 33 34 35 32 Pictured is unit only without bottle filler Uses HFC 134A refrigerant Usa refrigerante HFC 134A Utilise du fluide frigor...

Страница 3: ...MAINTAINING 6 152 mm MIN CLEARANCE FROM CABINET LOUVERS TO WALL ASEGURE UNA VENTILACI N ADECUADA MANTENIENDO UN ESPACIO E 6 152 mm M N DE HOLGURA ENTRE LA REJILLA DE VENTILACI N DEL MUEBLE Y LA PARED...

Страница 4: ...y los dos 2 tornillos en la parte superior Quite el panel frontal y p ngalo a un lado 6 Conectar el tubo de entrada de agua Ver la Nota 4 en las Instrucciones Generales 7 Quite la tuerca de retenci n...

Страница 5: ...e l appareil c t inf rieur du panneau distributeur NOTE S il y a d bit continu la fin du cycle du compresseur tournez la commande d eau froide vers le c t gauche de 1 4 de tour Mecanismo de la V lvula...

Страница 6: ...from the wall mounting plate installed on wall Make sure round boss in gasket fits in hole of basin See Fig 12 9 Once Bottle Filler is installed on wall plate tabs water line and power cord are insta...

Страница 7: ...ay will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the but...

Страница 8: ...ilter Head Fitting includes John Guest Fittings Assy Filter Bracket includes Fltr Head Mtg Bkt John Guest Ftgs Screws 1 2 3 55898C 98926C 0000000746 Ensamblado del Filtro 3000 Gal n Kit filtro cabeza...

Страница 9: ...e 1 4 x 1 4 x 3 8 Pack de 3 Coude Kit 75583C 5 16 1 4 Pack de 3 Kit de Remplissage de Bouteille de Vidange Kit Plaque Plug Coude crou de Vidange Panneau Front Bas Plaque Signal tique PV Panneau Front...

Отзывы: