background image

97716C (Rev. A - 5/02)

HRFG - ER*A   HRFG - SR*A   HRFG - SER*A

Halsey Taylor Owners Manual

Refrigerated Marblyte Fountains with Back Panel

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK

INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN

INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING

THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER

SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING

PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

HRFG - ER

HRFG - SR

HRFG - SER

To assure you install this model easily and correctly, PLEASE

READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING

THE INSTALLATION. CHECK YOUR INSTALLATION FOR

COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER

APPLICABLE CODES. After installation, leave these instruc-

tions inside the fountain for future reference.

Installer

All manuals and user guides at all-guides.com

all-guides.com

Содержание HRFG-ER

Страница 1: ...ER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BYTHE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLU...

Страница 2: ...FG ER A HRFG SR A HRFG SER A FIG 1 PAGE 2 HRFG ER SR ROUGH IN LEGEND A 3 8 O D TUBE WATER OUTLET B 3 8 O D TUBE WATER INLET C 1 1 4 O D WASTE TUBE NOT INCLUDED FINISHED FLOOR All manuals and user guid...

Страница 3: ...RFG ER A HRFG SR A HRFG SER A PAGE 3 FIG 2 HRFG SER ROUGH IN LEGEND A 3 8 O D TUBE WATER OUTLET B 3 8 O D TUBE WATER INLET C 1 1 4 O D WASTE TUBE NOT INCLUDED FINISHED FLOOR All manuals and user guide...

Страница 4: ...DAMAGE TO THE O RINGS MAY RESULT 7 These products are designed to operate on 20 105 PSIG supply line pressure If inlet pressure is above 105 PSIG a pressure regulator must be installed in the supply l...

Страница 5: ...EASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG 4 OPERATION OF QUICK CONNECT FITTINGS FIG 3 NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 4 O D...

Страница 6: ...2 HRFG ER A HRFG SR A HRFG SER A FIG 6 5 13 6 BASIN 2 9 10 16 7 SEE FIG 5 TOP VIEW 15 24 18 1 25 11 14 17 12 8 3 4 SEE FIG 6 23 FIG 7 PAGE 6 19 26 All manuals and user guides at all guides com a l l g...

Страница 7: ...R A HRFG SER A PAGE 7 CHILLER INLET 21 20 CHILLER OUTLET 12 TO BUBBLER HRFG ER SR TUBE ROUTING HRFG SER TUBE ROUTING TO BUBBLER TO BUBBLER 12 22 CHILLER OUTLET CHILLER INLET 20 FIG 8 FIG 9 All manuals...

Страница 8: ...45736C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 DESCRIPTION FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 323 0620 2222 CAMDEN COURT OAKBROOK IL60523 630 574 3500...

Отзывы: