HACFSCDWSBL*1F, 2F HACFSCDWSBLNF*1F HAC8FSCWSBLQ*1F, 2F HAC8FSCWSBLNFQ*1F HAC8FSCWSBLRNFQ*1F
Page 7
1000001743 (Rev. P - 01/19)
TOP COVER
MOUNTING
SCREWS
Fig. 8
Fig. 9
39
7/16” BOLT HOLES FOR
FASTENING UNIT TO WALL
UNIT CENTER LINE
Fig. 11
Fig. 10
Bottle Filler Installation Instructions
1)
Remove two (2) mounting screw
s with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 9). Remove top cover. Note do not discard mounting
screws, they will be needed to reinstall top cover.
2)
Remove wall mounting plate from Bottle Filler.
Place wall plate against wall on top of basin. Center the wall plate side to side with the basin. Mark
the six (6) mounting holes with a pencil (See Fig. 8).
3)
Remove wall mounting plate from wall.
NOTE
: Mounting plate
MUST
be supported securely. Add fixture support carrier if wall will not provide adequate
support.
4)
Install wall mounting plate to wall
using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 8). Use appropriate fasteners for
your wall type.
5)
Feed power cord & 3/8” water line
through hole in tower/basin gasket (See Fig 10).
6)
Install gasket on bottom of bottle filler tower
with gasket support bracket & (2) screws (See Fig 11).
7)
Lay Bottle Filler on water cooler basin
and cut insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube, but do not discard.
Feed the power cord and waterline through the hole on top of water cooler. NOTE: To prevent scratching the basin place a towel or soft
cloth over the entire basin when working above it.
8)
With the power cord and waterline through hole
on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall
mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 14).
9)
Once Bottle Filler is installed on wall plate tabs,
water line and power cord are installed properly, push top of Bottle Filler toward
wall and line up top cover two (2) holes.
10)
Reinstall Top Cover on Bottle Filler
(See Fig. 9) with two mounting screws from step 1 above. Caution, do not over tighten screws.
11)
Install remaining tube insulation
to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line to the tee.
12)
Install filter cartridge,
remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter
clockwise. NOTE: If existing plumbing rough in locations (Drain, Water In, and Electric Supply) do not allow the filter to be mounted inside the cooler cabinet
the filter can be installed horizontally below the unit. A retrofit kit is available to mount the filter beneath the cooler.
13)
Turn water supply on
and inspect for leaks. Fix all leaks before continuing.
14)
Once unit has been inspected for leaks
and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or
switch the circuit breaker back to the “ON” position.
15)
Once power is applied to Bottle Filler
, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.
16)
Verify proper dispensing by placing cup,
hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses
might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
17)
Once unit tests out,
install Lower Panel back on water cooler(s). Unit is now ready for use.
BRACKET & SCREWS
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115