Maintenance

Nozzle Cleaning and Alignment
To keep your HaloFogger® EXT working at optimum performance, it is recommended that you clean the 
nozzle on a regular basis (example: clean nozzle once-a-week if fogger is used once-a-day or more.)

Step 1.   Before performing any maintenance to the HaloFogger EXT, disconnect the power cord from 
the electrical outlet.

Nozzle Insert

Main Bolt

IMPORTANT - Position Main Bolt so a uniform gap 
surrounds the nozzle tip. 

Step 2.   Remove Nozzle. Using a 5/8” wrench, carefully 
turn nozzle counter-clockwise 90º and remove.

Step 3.   Separate Parts. Remove Main Bolt from Nozzle 
Insert. Soak both parts in  soap and water. Rinse parts 
thoroughly with water.

Step 4. Reassemble Nozzle. Carefully insert the Main 
Bolt back into the Nozzle Insert. Make sure the “wings” on 
the Main Bolt nest into the slots down inside the Nozzle 
Insert. 

Step 5. Carefully reinstall the nozzle into the Halo,  
turning nozzle clockwise 90º to lock into place. Test Halo 
for straightness of nozzle stream. 

Funnel Cleaning

The fluid funnel inside the HaloFogger EXT should be checked for debris on a regular basis.  Visually inspect 
the funnel. If any debris is present, wipe with a clean towel dampened with water.  

Ensure that the funnel screen is in place.

HaloFogger® EXT Operation Manual_1911

Содержание HaloFogger EXT

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Operation Manual 110V 220V EXT 1911 EXT...

Страница 2: ...n and dispensing disinfectant The room should be unoccupied Large Wheels For easy maneuvering Power Cord Connection Reservoir Drain High Precision Nozzle Dry mist of disinfectant is dispensed through...

Страница 3: ...lashing or overfilling which could harm the user and or the device 12 Halosil International is not responsible for any injury or damage caused by using this device outside of the specific parameters d...

Страница 4: ...ger EXT without the extended nozzle hose assembly fully connected Damage will occur Filling Instructions 1 Open the HaloFogger EXT Reservoir Door by lifting front edge of door 2 Locate the disinfectan...

Страница 5: ...r wheel 4 Take the clear tubing provided and drop one end into the waste bottle 5 Working the adjustable ball joints of the nozzle assembly mounting arm point the nozzle straight down Then move the no...

Страница 6: ...determine if the measured H2O2 level has dropped to about 1 ppm or below C If no written protocol has been established and you have no H2O2 sensor assume a waiting time of AT LEAST 110 MINUTES AFTER F...

Страница 7: ...r data logger via Bluetooth The HaloLog App does not need to be connected to a fogger before a treatment run is started The on board data logger captures all of the operating data which can be reviewe...

Страница 8: ...ll be displayed 4 To initiate a connection tap on any HaloFogger serial number displayed on the Halo List Screen When the connection is made the Run Events Screen will appear The top row of the screen...

Страница 9: ...and total Run Time for that HaloFogger highlighted in GREEN The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth handshake has been established which is...

Страница 10: ...nts will identified BILLABLE as a default Events that are not treatments a test run for example can be identified as NON BILLABLE These events will not appear in the downloadable CSV file but will be...

Страница 11: ...ddress A keyboard will appear to enter address ACTION Tap to email data The iDevice s email screen will open to confirm message ACTION Tap SEND in upper right corner of screen to send message Back up...

Страница 12: ...o a HaloFogger 2 In the event that HaloLogs of the same HaloFogger have been downloaded to multiple devices If one user has made changes to the HaloLog for example added room building or operator info...

Страница 13: ...remove Step 3 Separate Parts Remove Main Bolt from Nozzle Insert Soak both parts in soap and water Rinse parts thoroughly with water Step 4 Reassemble Nozzle Carefully insert the Main Bolt back into...

Страница 14: ...power cord is plugged into both the fogger and the wall outlet Then check to see that the outlet is working The green status indicator light should be illuminated when properly set up The fuse is blow...

Страница 15: ...sembly 0750 000 includes retainer cap nozzle insert main bolt and O ring Re Order Number Part Part Number 110V HaloFogger EXT US and Canada 0753 110EXT 220V HaloFogger EXT 0753 220EXT HaloMist All Pur...

Страница 16: ...of room being treated CAUTION PRECAUCION DO NOT ENTER ENTERINO Room Fogging in Progress Treatment Date Start Time Estimated Room Re entry Time Refer to HaloMist Use Instructions to determine room re...

Страница 17: ...was purchased and the unit s serial number Proof of purchase may be required If Halosil International determines that the fogger qualifies for warranty coverage a Return Merchandise Authorization RMA...

Страница 18: ...uce infection rates at your facility by visiting www halosil com There you can find out more about the Halo Disinfection System download literature and case studies and find a distributor near you 91...

Отзывы: