The HaloLog app allows logged data to be sent to any email address  for reports, archiving and 
data back-up.

*

 

ACTION

: Tap 

Select the range of HaloLog ID’s for download by either manually specifying the starting 
and ending ID# or use pre-select buttons to choose a particular selection. The iDevice will 
remember the ID# of the “last sent” for each HaloFogger.

 

ACTION

: Tap on the e-mail addresses to which data is to be sent . For convenience,  

 

the last e-mail entered address will be displayed by the iDevice. 

Tap 

 

 

 

 

 

to enter new email address. 

A keyboard will appear to enter address.

 

ACTION

: Tap 

                 to email data. 

 

The iDevice’s email screen will open to confirm message. 

 

ACTION

: Tap SEND in upper right corner of screen to send message. 

Back-up data from the HaloFogger® regularly by sending your data by e-mail to a secure 

address. Regular back-ups are the best and only protection against hardware failures.

To remove the DELETED identifcation from a Run Event

 

ACTION:

 Tap on the 

RED

 highlighted Run Event

 

ACTION:

 Tap  

   

  

A confirmation window will appear. Tap ‘Ok” to continue. 

The 

RED

 highlight and word 

DELETE

 are removed. 

Tap  

 

      to return to Run Event Screen. 

UnDelete

Done

Email Screen

Send Now

Email

Touch here to enter email address #1

HaloFogger®  EXT Operation Manual_1911

Содержание HaloFogger EXT

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Operation Manual 110V 220V EXT 1911 EXT...

Страница 2: ...n and dispensing disinfectant The room should be unoccupied Large Wheels For easy maneuvering Power Cord Connection Reservoir Drain High Precision Nozzle Dry mist of disinfectant is dispensed through...

Страница 3: ...lashing or overfilling which could harm the user and or the device 12 Halosil International is not responsible for any injury or damage caused by using this device outside of the specific parameters d...

Страница 4: ...ger EXT without the extended nozzle hose assembly fully connected Damage will occur Filling Instructions 1 Open the HaloFogger EXT Reservoir Door by lifting front edge of door 2 Locate the disinfectan...

Страница 5: ...r wheel 4 Take the clear tubing provided and drop one end into the waste bottle 5 Working the adjustable ball joints of the nozzle assembly mounting arm point the nozzle straight down Then move the no...

Страница 6: ...determine if the measured H2O2 level has dropped to about 1 ppm or below C If no written protocol has been established and you have no H2O2 sensor assume a waiting time of AT LEAST 110 MINUTES AFTER F...

Страница 7: ...r data logger via Bluetooth The HaloLog App does not need to be connected to a fogger before a treatment run is started The on board data logger captures all of the operating data which can be reviewe...

Страница 8: ...ll be displayed 4 To initiate a connection tap on any HaloFogger serial number displayed on the Halo List Screen When the connection is made the Run Events Screen will appear The top row of the screen...

Страница 9: ...and total Run Time for that HaloFogger highlighted in GREEN The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth handshake has been established which is...

Страница 10: ...nts will identified BILLABLE as a default Events that are not treatments a test run for example can be identified as NON BILLABLE These events will not appear in the downloadable CSV file but will be...

Страница 11: ...ddress A keyboard will appear to enter address ACTION Tap to email data The iDevice s email screen will open to confirm message ACTION Tap SEND in upper right corner of screen to send message Back up...

Страница 12: ...o a HaloFogger 2 In the event that HaloLogs of the same HaloFogger have been downloaded to multiple devices If one user has made changes to the HaloLog for example added room building or operator info...

Страница 13: ...remove Step 3 Separate Parts Remove Main Bolt from Nozzle Insert Soak both parts in soap and water Rinse parts thoroughly with water Step 4 Reassemble Nozzle Carefully insert the Main Bolt back into...

Страница 14: ...power cord is plugged into both the fogger and the wall outlet Then check to see that the outlet is working The green status indicator light should be illuminated when properly set up The fuse is blow...

Страница 15: ...sembly 0750 000 includes retainer cap nozzle insert main bolt and O ring Re Order Number Part Part Number 110V HaloFogger EXT US and Canada 0753 110EXT 220V HaloFogger EXT 0753 220EXT HaloMist All Pur...

Страница 16: ...of room being treated CAUTION PRECAUCION DO NOT ENTER ENTERINO Room Fogging in Progress Treatment Date Start Time Estimated Room Re entry Time Refer to HaloMist Use Instructions to determine room re...

Страница 17: ...was purchased and the unit s serial number Proof of purchase may be required If Halosil International determines that the fogger qualifies for warranty coverage a Return Merchandise Authorization RMA...

Страница 18: ...uce infection rates at your facility by visiting www halosil com There you can find out more about the Halo Disinfection System download literature and case studies and find a distributor near you 91...

Отзывы: