background image

Figure 4: Dimensional Drawing – EXPTA Actuator Assembly                                                 

Figure 5: Dimensional Drawing – EXPHL1 Actuator Assembly                                                

Operating Instructions: Alfred Solenoid Controlled Guard Lock

13

Figure 6: Dimensional Drawing – EXPTN and EXPTS Slidebar Actuator        

FORTRESS

A               company

Halma

www.fortressinterlocks.com

THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd. 

THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE 

DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.

ALL DIMENSIONS

ARE IN mm UNLESS

OTHERWISE STATED

A3

SCALE:

0.75

SHEET:

1 OF 1

ORIGINAL SIZE

DATE:

25-02-21

ISSUE:

0

EXPTA  - ALFRED TONGUE ACTUATOR

DWG NO:

SD-00034

FORTRESS

A               company

Halma

www.fortressinterlocks.com

THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd. 

THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE 

DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.

ALL DIMENSIONS

ARE IN mm UNLESS

OTHERWISE STATED

A3

SCALE:

0.50

SHEET:

1 OF 1

ORIGINAL SIZE

DATE:

25-02-21

ISSUE:

0

EXPHL1  - ALFRED HINGED HANDLE ACTUATOR

DWG NO:

SD-00035

FORTRESS

A               company

Halma

                www.fortressinterlocks.com

THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd. 

THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE 

DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.

ALL DIMENSIONS

ARE IN mm UNLESS

OTHERWISE STATED

A3

SCALE:

0.50

SHEET:

1 OF 1

ORIGINAL SIZE

DATE:

25-02-21

ISSUE:

0

EXPHL1  - ALFRED HINGED HANDLE ACTUATOR

DWG NO:

SD-00035

FORTRESS

A               company

Halma

www.fortressinterlocks.com

THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd. 

THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE 

DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.

ALL DIMENSIONS

ARE IN mm UNLESS

OTHERWISE STATED

A3

SCALE:

0.45

SHEET:

1 OF 1

ORIGINAL SIZE

DATE:

25-02-21

ISSUE:

0

EXPTN & EXPTS  - ALFRED SLIDEBAR ACTUATORS

DWG NO:

SD-00036

(2 PLACES)

2 OFF M8    10 HOLES

(ACCESS FROM THE REAR)

2 OFF    5.5 HOLES

(ACCESS FROM THE FRONT)

SLOT

(2 PLACES)

TO T

ONGUE

(2 PLACES)

TO TONGUE

(2 PLACES)

MAX . EXTENSION

THRU HOLE

(4 PLACES)

(2 PLACES)

(2 PLACES)

FULL RETRACTION

SLOT WIDTH

SLOT LENGTH

AT MAX. EXTENSION

Содержание FORTRESS Alfred

Страница 1: ...operating instructions enclosed It must be installed by competent and qualified personnel who have read and understood the whole of this document prior to commencing installation If the equipment is u...

Страница 2: ...65 3 4 When used for a Group III application the adhesive labels and non metallic coatings may store electrostatic charge and become a source of ignition Guidance on protection against the risk of ign...

Страница 3: ...750mm Can be fitted in two positions at 90 to either hinged or sliding door gates Description Part No Handing Hinged Handle Assembly EXPHL1 Front Integrated handle for guarding applications with hinge...

Страница 4: ...21 ALFRED SAFETY SWITCH OPERATING INSTRUCTIONS IMAGES DWG NO SD 00 2 LEFTHAND FACING DIRECTION OF ACTUATOR ENTRY 1 FRONT FACING HEAD 3 REAR FACING 4 RIGHTHAND FACING Head Modules Description Part No H...

Страница 5: ...hinery that is required to be isolated before access Safety Key Adaptors Used to provide a personnel key function to prevent unexpected machine start up Extracted Key Adaptor Also used as a personnel...

Страница 6: ...dard dustcover Description Part No Extracted Key Adaptor EKL7 Master lock type standard dustcover Description Part No Extracted Key Adaptor EKL3 Standard lock type padlockable dustcover Description Pa...

Страница 7: ...olenoid EXPXL416 Power to Unlock device Dual Safety Circuits change state on opening closing of a guarded area or operation of an interlocked key Monitoring circuit on Solenoid action provides feedbac...

Страница 8: ...channel Solenoid Voltage N A 24V DC 10 Solenoid Power Rating N A 350mA max 24V DC Solenoid Rating Duty Cycle N A 100 Transient Overvoltages Installation N A Category III Cable Size N A 28 12 AWG Diagn...

Страница 9: ...depending on product selection and configuration See specific functioning section below With Solenoid de energised the Internal mechanism of the Power to Unlock Ex Rated Solenoid Module automatically...

Страница 10: ...Monitor Circuit opens breaks Safety Circuits remain closed Gate Monitor Circuit remains broken Unlocking De Energise the Solenoid Internal locking mechanism dis engages to remove locking force from th...

Страница 11: ...k product An Extracted style Key Adaptor will always be located closest to the Head Module If Extracted style and Safety style Key Adaptors are configured together their operation sequence will combin...

Страница 12: ...essinterlocks com THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC WRITTEN APPRO...

Страница 13: ...FORTRESS INTERLOCKS Ltd THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC WRITTEN APPROVAL ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED A3 SC...

Страница 14: ...ntenance procedures are all easily possible All fixing screws used to mount the complete Alfred Solenoid Controlled Guard Lock product must be permanently prevented from removal If mounting fixings ar...

Страница 15: ...ATE 25 02 21 ISSUE 0 ALFRED SAFETY SWITCH OPERATING INSTRUCTIONS IMAGES DWG NO SD 00033 Operating Instructions Alfred Solenoid Controlled Guard Lock 15 Electrical Connection and Installation Tools and...

Страница 16: ...Circuit and terminal 13 Solenoid Monitor Circuit Terminal 12 Guard Open Output Signal Control signal produced by the Ex Rated Solenoid Module to indicate that the Machine Guarding is in an open state...

Страница 17: ...3 14 INTERNAL EARTHING POINT SHALL BE USED FOR EQUIPMENT GROUNDING CONNECTION FIX WITH M4 FIXING SCREW SUPPLIED SEE OPERATING INSTRUCTIONS FOR DETAILS XPXL471 13 3 4 EXTERNAL EARTHING POINT SHALL BE U...

Страница 18: ...ard Lock product If damage or wear is found with an assembly please contact your local Fortress Channel Partner The complete interlock must be replaced after 1 million switching operations Disposal Th...

Страница 19: ...the declaration described above is in conformity with the relevant Union harmonisation legislation 2014 34 EU The following harmonised standards and other technical specifications were used in suppor...

Страница 20: ...e is in conformity with the relevant Union harmonisation legislation 2014 34 EU The following harmonised standards and other technical specifications were used in support of this declaration Harmonise...

Отзывы: