16
Junction box material
ATEX: Glassfilled nylon
UL Version: Aluminium
316 Stainless Steel (optional)
Dimensions
156 x 166 x 111 mm (6.1 x 6.5 x 4.3 inches)
Weight
Alumnium: 1 kg (2.2 lbs)
Glassfilled Nylon: 0.5 kg (1.1lb)
Stainless Steel: 3.1 kg (6.8lbs) approx.
Operating voltage
8–30 V dc
Output
420 mA Sink (loop powered)
Fault signal
< 3 mA
Operating temperature
20°C to +50°C (4°F to +122°F)
dependant upon sensor type
Humidity
0–90% RH, non condensing
Degree of protection
IP65, IP66 (when fitted with a weatherproof cap)
Explosion protection
Intrinsically Safe
Approval code
ATEX
II 1 G EEx ia IIC T4
IECEx BAS 05.0042X
Tamb = 40°C to 55°C
UL& cUL Class I, Division 1, Groups A, B, C & D
Safety certificate no.
ATEX Baseefa04ATEX0115X
Standards
EN50014, EN50020, UL913
Zones
Certified for use in Zone 0, Zone 1 or Zone 2
(see hazardous area classifications section)
Gas groups
IIA, IIB, IIC (UL groups A, B, C, D)
EMC
EN50270
Marine Approval
Oxygen detectors only: MED (Marine
Equipment Directive 96/98/EC).
4. Specification
Xgard Type 1