background image

 

29

Boyertown Furnace Limited Warranty

 

Boyertown Furnace Company, Inc. (“Boyertown”) hereby warrants to the original consumer purchaser (“Purchaser”) that all equipment 

manufactured for and bearing Boyertown’s nameplate to be free from defects in workmanship or material for a period of years as indicated below 
under normal use and service at a firing rate of number (2) oil not exceeding that shown on its rating plate on all models of Boyertown Furnace.  If 
any such equipment sold by Boyertown proves to be defective in workmanship and material and if such part is within the indicated months below 
from the date of original installation returned to our factory, transportation charges prepaid, said part will be replaced or repaired, free of charge, 
F.O.B. Factory.

  

Purchaser’s remedy shall be limited to such repair or replacement and shall be purchaser’s exclusive remedy. 

 

The purchaser, by acceptance of this equipment, will assume all liability for the consequences of its use or misuse by the purchaser, his 

employees, and all other persons.  All warranties are based upon the return of the defective part to the Factory for examination, and purchaser shall 
assume responsibility and liability for transportation and labor costs. 

 

Boyertown shall not be liable for any consequential damages resulting from breach of this or any other warranty, express or 

implied

.

 

 Some states do not allow the exclusion or limitations on relief such as incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.  Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to 
you. 

 

  Model 

 Warranty 

Period 

Years 

Warranty Period Months 

 

 

Hallmark  

   

    5 

 

 

    60 

 

 

Regal 

 

 

    1 

 

 

    12 

 
 

Heat Exchanger – Residential Single Family Limited Warranty  

In addition to the above limited warranty, Boyertown warrants to the original consumer purchaser at the original installation address in a single 

family dwelling a limited “lifetime” warranty and adjustment policy on the heat exchanger.  In the event that any defect in material and workmanship 
is found to exist by Boyertown Furnace Company within twenty years (20) of the original installation, Boyertown Furnace Company will at its 
option, with the serial number and proof of purchase by the original consumer purchaser, furnish a replacement, or repair the heat exchanger.  In the 
event that any defect in material and workmanship is found to exist by Boyertown Furnace Company after twenty (20) years of the original 
installation, Boyertown Furnace Company will at its option, with the serial number and proof of purchase by the original consumer purchaser, 
provide  a new heat exchanger at fifty percent (50%) of the then current list price, or allow a credit in the amount of fifty percent (50%) of the then 
current list price of an equivalent heat exchanger toward the list price purchase of an equivalent manufactured Boyertown Furnace Company unit. 
Proof of purchase will be required of the original purchaser when the claim is made.  The purchaser must pay all other costs of warranty services, 
including labor costs involved in diagnostic calls, or in removing, servicing, or replacing warranty parts and or freight charges. 

 

 

Heat Exchanger – Commercial Limited Warranty  

In addition to the above limited warranty, Boyertown warrants to the original consumer purchaser at the original installation address, being other 

than a single family residence a ten (10) year warranty on the heat exchanger.  In the event that any defect in material and workmanship is found to 
exist by Boyertown Furnace Company within ten years (10) of the original installation, Boyertown Furnace Company will at its option, with the serial 
number and proof of purchase by the original consumer purchaser, furnish a replacement, or repair the heat exchanger.  Proof of purchase will be 
required of the original purchaser when the claim is made.  The purchaser must pay all other costs of warranty services, including labor costs 
involved in diagnostic calls, or in removing, servicing, or replacing warranty parts and or freight charges. 

 

Any Implied warranty relating to the heat exchanger covered by this warranty, including that of merchantability and fitness for 

a particular purpose shall be limited to the period of this limited warranty. 

 

Boyertown shall not be liable for any consequential damages resulting from breach of this or any other warranty, express or 

implied

.  

Some states do not allow the exclusion or limitations on relief such as incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.  Some states do not allow limitations on how long an implied warranty lasts, so the above may not apply to you. 

 

Purchasers Responsibilities 

In the event the original consumer purchaser believes there is a defect in material or workmanship, he shall, within thirty (30) days of the 

discovery of the defect, notify Boyertown in writing.  Boyertown or its authorized representative at its option will inspect the furnace and its 
component parts to determine whether a defect exists and recommend repair or replacement if necessary under the terms of the warranty.  If 
Boyertown determines that no such defect exists, purchaser may still pursue its remedies by commencing a civil action, but must do so

 within (1) 

year after the cause accrued.  

Some states do not allow this (1) year limitation, so it may not be applicable to you. 

This warranty will not be applicable if the furnace has been damaged as a result of being improperly serviced, or operated, including but not 

limited to the following: 

A)  If the furnace is used or operated over its rated capacity, as shown on the rating plate, or installed for uses other than residential home 

heating or commercial heating as listed above. 

B)  The furnace not being connected to an adequate sized supply and return air ducts according to industry standards and/or restrictions of air 

flow through the furnace and duct system. 

C)  Furnace must be operated in an environment free from the effects of chlorinated hydrocarbons. 
D)  Furnace not being operated during each heating season. 
E)  Damages , defects or other losses that occur in anyway after the furnace or heat exchanger has been tampered with, or altered in any way, 

except as may be specifically directed in writing by Boyertown Furnace Company, and damages, defects or other losses arising from improper 
installation, adjustment or servicing of the furnace or heat exchanger. 

F)  No warranty is given to any equipment which has not been installed by a qualified installer according to the regulations of the National Fire 

Protection Standard for Oil Burning Equipment, NFPA No. 31 and in complete accordance with all existing local codes, regulations, ordinances, and 
authorities having jurisdiction.  A qualified installer is an individual or agency responsible for the installation and adjustment of oil burning 
equipment.  The installer should be licensed and experienced to perform the installation of such equipment according to all codes and ordinances. 

G)  This warranty does not cover expenses for the removal or reinstallation.  The purchaser shall be responsible for the cost of removing and 

reinstalling the defective part including labor and material connected therewith.  Upon request of Boyertown, it shall be the obligation of the 
purchaser to ship prepaid to Boyertown the defective part for inspection or repair. 

H)  This warranty is applicable only to defects in material and workmanship and shall not cover failure of the furnace or any of its component 

parts due to any other reason including, but not limited to (1) lack of sufficient air flow, (2) floods, (3) fire, (4) acts of God, (5)  negligent or improper 
installation, (6) corrosion of heat exchanger surfaces, (7) leaky gaskets, (8) improper maintenance of external and fire side surfaces. 

Содержание Variable Speed 2 Stage

Страница 1: ...n and Operation Instruction Manual Variable Speed 2 Stage ECM Motor Keep these instructions with the furnace at all times for future reference Boyertown Furnace Co PO Box 100 Boyertown PA 19512 610 36...

Страница 2: ...our oil fired furnace is designed to burn No 1 and No 2 heating oil only Never use gasoline or a mixture of gasoline and oil Do not store gasoline or other flammable vapors and liquids in the vicinity...

Страница 3: ...Venting Chimney Relining Chimney Connector Power Venting Vent Dampers Ventilation and Combustion Air 14 Burner Installation 15 Wiring 16 Power Thermostat Oil Tank and Piping 19 Start Up 20 Start Up Eq...

Страница 4: ...24 53 37 1 2 12 10 27 5 8 2 2 22 LB D 115 1 40 00 0 115 0 00 6 80 0 2 0x2 0 150 0 16 00 4 435 4 5 24 42 38 1 2 12 10 20 2 2 22 LB D 85 1 05 00 0 88 00 0 6 82 6 1 6x2 0 117 5 14 00 3 1 2 385 4 2 23 38...

Страница 5: ...such installation provided the floor under the furnace is protected in accordance with the requirements of accepted building code practice and NFPA 31 The furnaces shall be permitted to be placed on...

Страница 6: ...Rear Sides Above Rear Sides 3 thick masonry wall without ventilated air space N A 12 N A 9 N A 6 N A 5 insulation board over 1 glass fiber or mineral wool batts 12 9 9 6 6 5 4 3 24 gauge sheet metal...

Страница 7: ...avoid condensation in the furnace heat exchanger The evaporator coil must be installed at least 6 above the heat exchanger for proper air flow Distances less than 6 will result in decreased air flow...

Страница 8: ...Area Sq In 600FPM Area Sq In 800FPM Area Sq In 1000FPM Area Sq In 1200FPM Area Sq In 1600FPM Area Sq In 2000FPM 50 12 100 24 18 14 12 150 36 27 22 18 14 200 48 36 29 24 18 14 250 60 45 36 30 23 18 30...

Страница 9: ...mode of operation the blower is to run Air flow rates in the different modes are controled by the setting of the DIP switches Standby Mode The thermostat inputs are being continuously monitored The m...

Страница 10: ...hange the air flow settings until the blower has come to a complete stop No change in air flow will occur unless the motor has been allowed to a complete stop See figure below for the location of the...

Страница 11: ...5 COOL 6 Y1 7 ADJUST 8 OUT 9 O 10 BK PWM 11 HEAT 12 R 13 EM W2 14 Y Y2 15 G 16 OUT Power connector Signal connector Figure 1 Figure 3Power Connector VENTING Failure to follow all instructions can res...

Страница 12: ...cracking from the flue gasses All chimney clean out doors and flue connections must fit tightly so they will seal to avoid air leakage The inside area of the chimney liner should equal at a minimum th...

Страница 13: ...tor shall not exceed 10 feet The chimney connector shall be installed so as to minimize the number of elbows and to avoid sharp turns or other construction features that would create excessive resista...

Страница 14: ...side wall by using a listed power side wall Venter The vent device must be able to produce a draft of 02 W C over the fire and be equipped with a post purge timer set to a minimum time of 5 minutes T...

Страница 15: ...from its shipping carton and inspect thoroughly Verify that the correct burner combination and nozzle is installed in the burner as shipped Read the oil burner manual included in the shipping carton a...

Страница 16: ...ments 2 Delavan nozzle 3 Hago nozzle Wiring Electric shock hazard can cause severe personal injury or death if power source including service switch for the furnace is not disconnected before installi...

Страница 17: ...17 17...

Страница 18: ...ed for AC operation the B terminal is for the reversing valve energized for HP operation When wiring for the first stage cooling choose the appropriate Y1 terminal for the air flow required When insta...

Страница 19: ...and across ceiling or floor joists Piping shall be supported and protected from physical damage and where necessary protected against corrosion as per code Piping systems shall be maintained liquid t...

Страница 20: ...l residue or foreign materials and that the refractory chamber has not been damaged 4 Check oil burner nozzle to ensure that the right size and type is installed and tight in the adapter See prelimina...

Страница 21: ...tings shown in Table 8 thru Table 10 are approximate The burner must be adjusted during actual field installed conditions Failure to do so will result in poor performance and nuisance service calls Af...

Страница 22: ...r or appliance The area around the furnace should be kept clear of all combustible materials Never attempt to burn garbage or refuse in the furnace Never attempt to light the furnace by throwing burni...

Страница 23: ...ay pattern Perform the combustion checks as per the burner manual and the furnace manual Blowers Direct Drive Clean inspect blower wheel annually Lubricate blower motor as per the motors recommendatio...

Страница 24: ...504100 504500 11 1 POUCHPLATE GASKET KIT 489000 489000 12 1 BAFFLE ASSEMBLY KIT 730317K 730317K 13 1 HEAT EXCHANGER KIT 730051K 730061K 14 1 FLUE COVER 740800 740800 15 1 REAR PANEL 504130 504530 16...

Страница 25: ...LB REAR AIR BAFFLE 504910 504910 14 1 SEPARATION PLATE 740763 740763 15 1 FLUE EXTENSION PIPE 732690 732691 16 1 REAR PANEL 504030 504430 17 1 FLUE COVER 740800 740800 18 1 DOOR 504040 504440 19 1 BLO...

Страница 26: ...es Oil Filter Clean Replace Oil Filter Pump Strainer Clean Clean or Replace Strainer Adjust Pressure Per Set up Label Refer to Burner Manual Pump Pressure Per Set up Label Spark Established Ignition E...

Страница 27: ...lts at Furnace 120 Volts at Burner Control Adjust Thermostat Check Supply Fuses and Disconnects Fan and Limit Operational Refer to Burner Manual Burner Off on Safety Refer to Burner Manual No No No No...

Страница 28: ...erify Correct Furnace Wiring Repair Wiring Replace Power Cord Yes 24 Volts R C on Terminal Strip Yes Replace Fan Center Relay No Check Wiring Replace Cable Place Jumper on R W 24VAC BetweenPins 1 2 Ch...

Страница 29: ...ger Proof of purchase will be required of the original purchaser when the claim is made The purchaser must pay all other costs of warranty services including labor costs involved in diagnostic calls o...

Страница 30: ...air flow and ACCA Manual D t Work All ducts sealed and insulated as required Burn Burner Model __________________ Nozzle _______GPH _______Deg _______Type_______ er Operation Burner Pump Pressure ___...

Страница 31: ...31...

Страница 32: ...Serial Number ________________________ Name of Purchaser _________________________________________________________________________ Purchaser s Address ________________________________________________...

Отзывы: