14
A flexible metal appliance connector used to connect the cooktop to the gas supply
line must have an internal diameter of 5/8”/1.6 cm and should be 3 feet/91.4 cm
max. in length for easy installation. In Canada, flexible connectors should be single
wall metal connectors less than 6 feet/182.9 cm in length.
Shut off the main gas supply valve before removing the old cooktop and leave it off
until the new hook-up has been completed. Don’t forget to relight the pilots on
other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the cooktop, the use of a CSA certified
flexible metal appliance connector is recommended unless local codes require a hard-
piped connection. Never reuse an old connector when installing a new cooktop. If
the hard piping method is used, you must carefully align the pipe; the cooktop
cannot be moved after the connection is made.
To prevent gas leaks, use pipe joint compound resistant NG. gases on all male
external pipe threads.
1.
In an easily accessible location, install a service manual gas shut off valve. Be
sure everyone operating the cooktop knows where and how to shut off the
gas supply to the cook top.
2.
Use a flexible gas line to connect to the 1/2” fitting, located on the bottom
of the cook top
3.
When all connections have been made, be sure all cooktop controls are in the
off position and turn on the main gas supply valve. Check for gas leaks by
using a 75% water, 25% dish washing soap solution. If a gas leak is present,
shut off gas immediately, tighten all connections, and retest for leaks.
4.
Any opening in the wall behind the appliance and in the floor under the
appliance shall be sealed.
Correct Flame Appearance