13
Tighten the cooktop to the underside of the counter until secure.
Install all burners and burner caps
Install all grates. Please be aware of the grate positioning on some models -
the holes in the grates must align over top of the burners.
Connecting gas to cooktop
This cooktop is designed to operate at a pressure of 4” of water column on natural
gas or 10” of water column on propane gas (LPG).
Make sure you are supplying your cooktop with the type of gas for which it is
designed.
It’s shipped for use with NG.
This cooktop is convertible for use on
natural gas (LPG) also. When using this cooktop on LPG gas, conversion must be
made by a qualified LPG installer before attempting to operate the cooktop on that
gas.
For correct operation, the pressure of natural gas supplied to the regulator should be
between 4” and 5” of water column. For LP gas, the pressure supplied must be
between 10” and 12” of water column.
When checking for correct operation of the regulator, the inlet pressure must be at
least 1” more than the operating manifold pressure as given above.
The pressure regulator located at the inlet of the cooktop manifold must remain in
the supply line regardless of whether natural or LP gas is being used.
Regulator is only good for ½ psi (14” w.c.) so test pressure must not exceed ½” psi.