7-1-2, AVC SCHEMATIC & VOLTAGE CHART
RECHECK S-METER ZERO AND S9 SETTINGS.
1, Warm up 15 minutes.
2, Turn RF gain to zero. Adjust meter zero pot for 0 on the S-meter.
3, Turn RF gain to max. Set generator for 5 microvolts output.
4, On 80 meters tune up @ 3.900 MHz. Insure both preselector and tuning are peaked.
5, Set generator for 50 microvolts output @ 3.900 MHz.
6, Set AF gain for 500 mw out. Set factory gain pot for S9 on meter.
AVC VOLTAGE CHART
For this test
NO SIG
= RF GAIN control set at 0.
S9
= RF GAIN set to 10.
PIN #
1
2
3
4
5
6
7
8
9
NO SIG
0.3
3.7
/////////
6.3vac
0.0
/////////
146.0
0.0
1.8
S-9
-4.1
4.1
///////// //////// ///////// /////////
145.0
0.0
1.78