![Hallicrafters SX-117 Скачать руководство пользователя страница 16](http://html2.mh-extra.com/html/hallicrafters/sx-117/sx-117_repair-manual_3380029016.webp)
16
5-2-1, SSB OSCILLATOR TEST
Power up in the configuration listed above. Connect the scope using a 10X probe to pin 7 of
V8. You should see a minimum of 5.0 vpp. Move the probe from the scope to the frequency
counter. You should read 1600KHz. Switch from LSB to USB. You should read 1700KHz on the
counter. Move the probe from the counter to the scope. You should see a minimum of 5.0
vpp. The amplitude of the signals on USB and LSB should be equal. Slight offset errors can be
corrected by the VFO CAL RESET; however, you will be required to readjust the CAL RESET each
time you change bands.
5-2-2, SSB OSCILLATOR SCHEMATIC & VOLTAGE CHART
PIN #
1
2
3
4
5
6
7
8
9
V8A
//////////
0
110
6.3vac
0
124
4.0
////////// //////////
V8B
172
////////// ////////// ////////// ////////// ////////// //////////
0.3
0
VOLTAGES ARE DC UNLESS OTHERWISE NOTED. You will need an RF blocking probe.
Содержание SX-117
Страница 1: ...1 WD GOF Walt Cates...
Страница 2: ...2...
Страница 14: ...14 Voltage patten seen on anodes of CR3 and CR4 Pattern is identical on both anodes...
Страница 32: ...32 9 APPENDIX 9 1 BULLETIN 1964 4...
Страница 33: ...33 9 2 ENGINEERING CHANGE C15E...
Страница 35: ...35...
Страница 36: ...36...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...39...
Страница 40: ...40...
Страница 41: ...41...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46 9 4 SERVICE BULLETIN RUN 5 CHANGE...
Страница 47: ...47 9 5 ENGINEERING CHANGE C 169 NOTE C level units will have the serial 117002 XXXXXX...
Страница 48: ...48...
Страница 49: ...49...