Command 

Response 

Description 

VER 

<SPACE>-----> vx.xx <-----<CR><LF> 
(There is a leading space) 

Show installed firmware version. 
Note there is a single leading space character 
in the response. 

FADEFAULT 

 

Set the device to factory defaults 

ETH_FADEFAULT 

 

Set IP settings to factory default 

REBOOT 

If a valid command is used, most likely 
there will be no response unless there was 
a command formatting error. 

Reboot the device 

HELP 

 

Show the list of available commands 

HELP N 
where N=command 

 

Show description of command specified 

RELAY N N1 
where N=1 
N1= OPEN, CLOSE, TOGGLE 

RELAY N N1<CR><LF> 

Relay control 

LEDBLUE N N1 
where N=1~8 
N1=0-100% 

LEDBLUE N N1<CR><LF> 

Individual button blue LED brightness control 

LEDRED N N1 
where N=1~8  
N1=0-100% 

LEDRED N N1<CR><LF> 

Individual button red LED brightness control 

LEDBLUES N 
where N=0-100% 

LEDBLUES N<CR><LF> 

Set the brightness of all blue LEDs 

LEDREDS N 
where N=0-100% 

LEDREDS N<CR><LF> 

Set the brightness of all red LEDs 

LEDSHOW N 
where N=ON/OFF/TOGGLE 

LEDSHOW N<CR><LF> 

LED demo mode 

BACKLIGHT N 
where N=0-100% 

BACKLIGHT N<CR><LF> 

Set the max brightness of all LEDs  

KEY_PRESS N RELEASE 

KEY_PRESS N RELEASE<CR><LF> 

Set the key press trigger type to “Release”. 

KEY_PRESS N HOLD 

KEY_PRESS N HOLD<CR><LF> 

Set the key press trigger type to “Hold”. 

MACRO RUN N 

RUN MACRO[N] EVENT.<CR><LF> 


where x = the macro commands 

Run the specified macro (button). 
The response also occurs if a button is 
pressed. 

MACRO STOP 

MACRO STOP<CR><LF> 

Stop all the running macros 

MACRO STOP N  
N=1~32 

MACRO STOP N<CR><LF> 

Stop the specified macro. 
 

DEVICE ADD N N1 N2 N3 
where 
N=1~16 (Device slot) 
N1=X.X.X.X (IP Address) 
N2=0~65535 (Port Number) 
N3={Name} (Up to 24 
characters) 

 

Add TCP/TELNET device in Slot N 
The name may not contain any spaces. 
 

DEVICE DELETE N 
where 
N=1~16 (Device Slot) 

 

Delete the TCP/TELNET device in Slot N 

DEVICE N N1 
where 
N=ENABLE, DISABLE 
N1=1~16 (Device Slot) 

 

Enable or Disable TCP/TELNET device in 
Slot N 

Содержание UI-IP8-DP

Страница 1: ...ur LAN using a single gang Decora Style Wall plate Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 Warner Ave Tustin...

Страница 2: ...tall the Hall Research Device Finder HRDF Software Tool 6 4 2 Login to WebGUI 8 4 3 Macro Settings Tab 8 4 4 Extension Macro Tab 11 4 5 Command Settings Tab 11 4 5 Device Settings Tab 12 4 6 Key Setti...

Страница 3: ...r can come from the compatible LAN network using PoE Power over Ethernet The UI IP8 DP includes integrated battery backed clock calendar allowing the user to send commands based on specific day time s...

Страница 4: ...VDC 2 6A Universal Power Supply 1 USB Type A to Mini USB OTG connector 1 Pre printed button labels 28 labels 1 Blank button labels 28 labels 1 User s Manual 3 0 Configuration and Operation 3 1 Install...

Страница 5: ...l use the keypad to trigger an additional device Model CNT IP 2 sold separately to send the desired RS 232 Serial commands Use UI IP8 DP with add on CNT IP 2 for control of RS 232 Devices In the above...

Страница 6: ...er 4 0 Configuration and Control via Web GUI 4 1 Install the Hall Research Device Finder HRDF Software Tool The default STATIC IP address as shipped from the factory or after factory default reset is...

Страница 7: ...Network button The software will list all of the UI IP8 DP devices found Other Hall Research devices may also appear if connected to the same network as the UI IP8 DP Hall Research Device Finder HRDF...

Страница 8: ...the systems functions 4 3 Macro Settings Tab The Macro Settings tab allows the user to edit the macro sequences assigned to each of the eight physical buttons Click on macros 1 6 to see various LED li...

Страница 9: ...Light slider adjusts the maximum brightness settings for ALL the LEDs For example if the slider is midway a command that sets brightness to 100 will shine at 50 When the mouse hovers over a button a...

Страница 10: ...interface where it will be sent and the delay time prior to the next command in the macro UI IP8 DP Command Interface The Delay ms field is the time to wait before proceeding to the next command if an...

Страница 11: ...button shown at the bottom of the list 4 4 Extension Macro Tab Click on the Extension Macro tab to execute edit an additional eight 8 macro buttons that are accessible via Web GUI only Settings in thi...

Страница 12: ...E To send the string PWR ON cr lf enter the command like this PWR ON x0d x0a Click on the Save Change button to save the command 4 5 Device Settings Tab The UI IP8 DP lets the user enter a maximum of...

Страница 13: ...Repeat only works with the physical keypad not in the webGUI Toggle Key Causes the button to toggle between the two listed macros regular and extension for the same button position for each press 4 7...

Страница 14: ...o the event 4 8 Network Settings Tab As shipped from the factory or after restoring factory defaults the UI IP8 DP IP address is set for static IP address 192 168 1 50 Network Settings If changes are...

Страница 15: ...ALL RESET button Reboot the Unit Used to reboot the UI IP8 DP without removing power Firmware Upgrade Used to update the firmware in the UI IP8 DP UI IP8 DP System Settings The system can automatical...

Страница 16: ...rminates each command One or more CR LF characters terminate each response Unknown commands respond with Command FAILED CR LF Command syntax errors respond with Wrong command format CR LF Command Resp...

Страница 17: ...00 LEDBLUES N CR LF Set the brightness of all blue LEDs LEDREDS N where N 0 100 LEDREDS N CR LF Set the brightness of all red LEDs LEDSHOW N where N ON OFF TOGGLE LEDSHOW N CR LF LED demo mode BACKLIG...

Страница 18: ...pgrade with the USB Cable Firmware upgrade is possible with or without a computer Power the UI IP8 DP while holding button 1 Button 1 will blink twice when ready to update firmware With an external co...

Страница 19: ...714 641 6607 To return the unit to Hall Research you must first get a Return Authorization RMA number Package the unit carefully if returning We recommend that you use the original container 8 0 Speci...

Страница 20: ...Copyright 2018 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Ph 714 641 6607...

Отзывы: