The wall plate can be used to 

control the display on/off function

 (Power 

Command). The wall plate can store and send RS232 control commands to 

displays or projectors with RS232 control capability. The wall plate can 
extend IR signals, by pointing IR remote to the wall plate and connecting 
an IR emitter to the Receiver, however the wall plate also has limited 
capability to generate user defined IR commands and some popular IR 
protocols are supported. Since there are thousands of IR commands and 

dozens of protocols, it may be difficult for the user to obtain all the 
information necessary for IR control. Using programmed IR commands is 
further complicated because to keep the power state of the wall plate 
synchronized with the TV, unique IR commands for ON and OFF are 

needed. Many TVs only have one IR command that toggles the state 
between on and off, making programmed IR control unsuitable.  
To configure the wall plate and enter RS232 power commands for your 
display, the wall plate provides a mini-USB connector (on the bottom side) 

and is shipped with a USB cable that can be connected to any Windows

®

 

PC.  A free Windows

®

 GUI software is available on the product's webpage. 

It is the user’s responsibly to determine, for their specific display, the 
control method and to obtain the commands from the display 

manufacturer.  
As mentioned earlier for best results use a display or a projector with an 
RS232 control port if you desire the wall plate to control its power. 

  

Supports MHL with charging feature

 

 

 

 

 

 

Содержание UHBX-SW3

Страница 1: ...QuickStartGuide VGA HDMI MHL Auto Switching WallPlate With Output UHBX SW3 WP QSG1229 Rev 1 2 ...

Страница 2: ...sor and can extend IR control signals to the Receiver For a few IR protocols if the format data and address bytes of the IR signal are known the wall plate may also be capable of generating the IR signals Using just a single twisted pair Cat6 cable the wall plate connects to a compatible receiver such as the model UHBX R PSE The single Cat6 cable carries all AV and control signals RS232 or IR from...

Страница 3: ...ake sure to use the one labeled as HDBaseT Output C Co on nn ne ec ct ti io on n t to o D Di is sp pl la ay ys s w wi it th h N Na at ti iv ve e H HD DB Ba as se eT T i in np pu ut ts s The Wall plate can be directly plugged in to displays or projectors with HDBaseT inputs In this configuration the wall plate still sends RS232 control commands to the display check your display s specifications for...

Страница 4: ...or IR control Using programmed IR commands is further complicated because to keep the power state of the wall plate synchronized with the TV unique IR commands for ON and OFF are needed Many TVs only have one IR command that toggles the state between on and off making programmed IR control unsuitable To configure the wall plate and enter RS232 power commands for your display the wall plate provide...

Страница 5: ...n the wall plate will issue that command at the same time it turns on So all you have to do is press the power button on the wall plate once 1 Press the power button 2 The red LED above the power button will turn on and also one of the 3 green LEDs next to the inputs will turn on to indicate which source is selected 3 To change input press the SOURCE button For each press the green LED next to eac...

Страница 6: ...ed off and back on it will recall this mode If the Auto Source mode is not locked by the GUI you can exit this mode from the wall plate by holding the Source button for 3 seconds The red LED above the Source button will turn off Notice The user can prioritize inputs in case more than one is active As shipped from factory HDMI 1 has the highest priority then HDMI 2 and last the VGA input So if the ...

Страница 7: ... LED above the power button will start blinking slowly This indicates that the wall plate will automatically send on and off commands to the display In this mode pressing the power button will not do anything If not locked from the GUI you can exit Auto Power Command mode by pressing and holding the Power button for 3 seconds The red LED above the Source button will stop blinking Now you can manua...

Страница 8: ...y event that the VGA image on the display is grossly misaligned press both power and source buttons on the panel simultaneously This will start the Auto Adjust procedure after resetting the wall plate takes about 15 seconds to complete C Co om mp po on ne en nt t V Vi id de eo o I In np pu ut t Using HD15 to 3 RCA cable the VGA input can accommodate component video YPbPr But you have to configure ...

Страница 9: ... panel on and off and issue corresponding commands to display Hold for 3 seconds to enter or exit Auto Power Command mode 3 VGA input selection indicator Can be configured for YPbPr 8 Power Indicator When lit solid the panel is on When blinking slowly it indicates Auto Power Command mode 4 Stereo audio input for VGA Can be configured to pass audio without VGA connected 9 IR Extension Detector Any ...

Страница 10: ... USB to mini USB cable is provided 3 For connection to SW3 UI and SW3 UI VOL optional auxiliary control panel sold separately C Co on nf fi ig gu ur ra at ti io on n U Us si in ng g t th he e U US SB B p po or rt t The wall plate is ready to use out of the box and in many cases no special configuration is needed If the user desires to control the On Off function of the display or to tweak some of ...

Страница 11: ...hese keypads plug to the UHBX SW3 WP using a Cat5 cable and can be located up to 200 ft away at a convenient location The SW3 UI duplicates all the controls and indicators that are on the wall plate It is perfect for monitoring and controlling the system from a convenient spot instead of using the buttons on the UHBX SW3 WP wall plate The SW3 UI VOL adds 3 additional buttons that can be tied to vo...

Страница 12: ...Hall Research 714 641 6607 Page 12 Copyright 2015 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Ph 714 641 6607 ...

Отзывы: