Hall Research Technologies TVB-400 Скачать руководство пользователя страница 11

 

 

 Video to PC/HDTV Switching Scaler 

Volume (TVB-400A only):

 Press 

or

 to adjust the Audio level. 

The range of adjustment is 0~63. Factory default value is 31. 
(TVB-400A Only). If the power is turned off, the volume level can 
still be adjusted by first pressing the ‘ADJUST’ button and then 
using the 

or

 buttons to adjust the Audio level. 

4

4

.

.

 

or

: Press to toggle through various adjustment controls to alter 

the settings  

________ Note ________ 

In the picture adjust mode, pressing 

 and 

 

simultaneously will revert the selected parameter back to 
factory preset value. Pressing both buttons for over 5 
seconds will revert all picture parameters back to their 
factory preset values. 

5

5

.

.

 IR Sensor: Infrared remote control sensor. 

6

6

.

.

 Power and LED button: Press once to power on the unit, press 

again to turn off. 

Note

: with power off the PC input is passed to the 

output. 

F

F

r

r

o

o

n

n

t

t

 

 

P

P

a

a

n

n

e

e

l

l

 

 

L

L

o

o

c

c

k

k

o

o

u

u

t

t

 

 

-

-

 Under certain circumstances it may be 

desirable to disable the front panel controls (e.g. to prevent 
unauthorized or accidental changes to the settings while the unit is in 
use).  To disable the front panel controls you must use the RS-232 port 
(see Serial Control section for details)  

It is still possible to remove the lockout from the front panel by 
performing a full factory default reset operation! 

To reset all parameters back to factory preset value, press the “Mode” 
and “Adjust” buttons simultaneously for over 10 seconds. The Power 
led will turn off while the buttons are depressed and turn back on when 
the software reset occurs. The default video output selection is 
Composite Video at XGA (1024x768) output resolution will be 
selected. 

Содержание TVB-400

Страница 1: ...r HDTV Component Output Front Panel IR Remote RS 232 Serial Control Order toll free in the U S 800 959 6439 FREE technical support Call 714 641 6607 or fax 714 641 6698 Mail order Hall Research 1163 W...

Страница 2: ...2...

Страница 3: ...ss A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are intended to provide reasonable protection against such interference when the equipment is ope...

Страница 4: ...Scaled Output 6 2 4 Other Connections 7 3 Configuration Operation 7 3 1 Front Panel 7 3 2 Infra Red Remote control IR Remote 10 4 Serial Control 10 4 1 Control Software Installation 11 4 2 Using the...

Страница 5: ...t various kinds of video inputs for your LCD The TVB 400A is the same as the TVB 400 but adds audio switching and volume control capabilities for line level audio The Video Scaler can be controlled in...

Страница 6: ...vice OSD On Screen Display with Blanking and Freeze functions Easy to use IR remote control State of the art frame buffer with time base correction Reverse 3 2 2 2 pull down provides clear and crisp d...

Страница 7: ...he output without scaling if desired Refer to Figure 2 1 for a block diagram Rear Panel S Video Use an S Video cable to connect the S Video output of the source video equipment to the connector labele...

Страница 8: ...VGA compatible LCD Projector or Plasma display It can also output HDTV compatible YPbPr in various formats as described below The same HD 15 connector is used to output VGA RGBHV output or HDTV YPbPr...

Страница 9: ...Mode Press the button repeatedly will toggle through the following adjustment controls Source Resolution Output Aspect 3D Enhance Digital NR Source mode While in this mode press or buttons to choose...

Страница 10: ...function Digital NR mode To turn on or turn off the digital noise reduction function Blanking mode To turn on or turn off the video blanking function Freeze Video mode To turn on or turn off the vide...

Страница 11: ...and LED button Press once to power on the unit press again to turn off Note with power off the PC input is passed to the output F Fr ro on nt t P Pa an ne el l L Lo oc ck ko ou ut t Under certain cir...

Страница 12: ...the RS 232 pressing this button for over 15 seconds will turn on the IR Sensor 17 3D Press to turn ON OFF the 3D enhance 18 NR Press to turn ON OFF the digital noise reduction 19 Mode Same as mode bu...

Страница 13: ...with the unit into the CD drive Run the SETUP EXE program The following screen is displayed Click the OK button and the following screen is displayed Click the button to continue the installation into...

Страница 14: ...n the future The AV Settings and Adjustment windows are by default not displayed Click the button to open or close the panel The PC Loop Bypass must be enabled which is the default setting in order to...

Страница 15: ...Clicking the AV Reset button will change all of these parameters back to there default settings o Adjustments These are the various settings that allow you to control Bypass OSD Digital NR 3D enhancem...

Страница 16: ...t 10 Value 0 63 default 31 VO value Volume Value 0 63 default 31 IR 0 IR 1 IR IR sensor OFF IR sensor ON FP 0 FP 1 Front Panel Front panel lockout ON Front panel lockout OFF TD 0 TD 1 3D Enhance 3 D e...

Страница 17: ...hen turn on again when the reset has occurred 5 2 Contacting Hall Research If you determine that your scaler is malfunctioning do not attempt to repair the unit Contact the Hall Research Technical Sup...

Страница 18: ...DIN YPbPr on 3 BNC PC on VGA HD15 Female Pixels Format Scan PC VGA 640x480 SVGA 800x600 XGA 1024x768 SXGA 1280x1024 RGBHV RGBHV RGBHV RGBHV Progressive Progressive Progressive Progressive Scaled Outpu...

Страница 19: ......

Страница 20: ...Copyright 2009 Hall Research Inc All rights reserved 1163 Warner Ave Tustin CA 92780 Ph 714 641 6607 Fax 714 641 6698...

Отзывы: