In hard water conditions it is recommended that you periodically 
remove the pump from the water feature and operate it for up to 
36 hours in a solution of CLR (Calcium Lime Rust Remover) and 
water. Rinse thoroughly before re-installing the pump in the water 
feature. 

  

Disassembling the Pump  

 

Follow these step by step instructions if the pump requires more 
intensive cleaning.  

 

Unscrew down cover and take it from the pump housing. 

 

Loosen and remove the 4 outer screws and the 4 screws in the 
middle. 

 

Remove the output assembly from the upper cover. 

 

Remove the impeller from the pump body. 

 

Clean  all  parts  using  water  and  a  soft  sponge.  In  hard  water 
conditions a mixture of CLR and water bath is recommended. 

 
Assembling the pump together 

 

Place the impeller in the pump body with caution. 

 

Make sure the impeller is assembled correctly and will turn freely 
and check the position of the sealing ring on the pump body. 

 

Line the pump body up with the groves on the output assembly 
and tighten the (8) uniformly. 

 

Place the down cover on and tighten the screws uniformly. 

 

Questions? 

  

Please call us 1-866-831-6558 or email [email protected] 

 
 

CAUTION 

These  pumps  are  not for  use in  swimming  pools! Swimming in  water  being 
circulated  or  oxygenated  by  these  pumps  poses  a  severe,  imminent  and 
potentially fatal risk to human health.   
 
These pumps should be installed per your local electrical code. Please contact 
an electrician. For all technical data, please refer to the content stated on the 
rating label of the pump. 
 
Do not operate these pumps without water. If the pump runs, for any length of 
time, dry without water it will damage the pump and void the warranty.  

 
 

 
 

Safety Instructions

 

 

Read and observe all the instructions supplied with the pump and on 
the pump. 

 

Make sure that your outlet voltage corresponds to those stated on the 
rating label of the pump(s). 

 

Make sure the pump is securely installed before operating it. 

 

The electrical connection should be in a water-proof area and should 
be at least 6 feet away from the edge of the pond. (see fig. 1) 

 

Keep the electrical connections dry! Droop the electrical cord below 
the electrical outlet to form a “Drip Loop”. This will prevent water from 
running down the cord into the electrical outlet 

 

Always unplug the pump when not in use, before putting on or taking 
off parts, before cleaning the pump and before doing any work for the 
fountain or pond. 

 

The pump must not be used when people are working in water. Please 
disconnect the pump first. 

 

Do  not  operate  any  appliance  with  a  damaged  cord  or  plug,  or  in 
abnormal state. The supply cord of the pump cannot be replaced.  

 

 

If the cord is damaged the pump should be scrapped.

 

 

 

Do not cut the plug end off the cord for any reason. Cutting the 
cord voids the warranty and may create an electrical hazard. 

  

 

For  safety  reasons,  any  repair  work  should  be  done  only  by  the 
manufacturer  of  the  products  or  the  authorized  service  facility  or 
discard it 

 

Never hang or transport the pump by means of pulling the power cord! 

 

Close  supervision  is  necessary  when  the  pump  is  used  by  or  near 
children. 

 

If you want to disconnect the pump, you can pull out the plug and the 
plug must be placed where you can access it. 

 

Never use any accessories which are not recommended by the pump 
manufacturer.  It  may  result  in  fire,  electric  shock,  personal  injury 
and/or voided warranty. 

 

The pump is to be supplied through a Ground Fault Circuit Interrupter 
(GFCI) with a rated residual operating current not exceeding 30mA. 

 

To protect against the risk of electrical shock, do not immerse the plug-
in water or other liquid. 

 
 
 
 
 