Installation
122
Basic Installation
Hale Products, Inc., August - 06, Rev-B
THE TBP PUMP CAN OPERATE AT PRESSURES IN EXCESS OF 600PSI.
MAKE SURE TRUCK PLUMBING IS CAPABLE OF WITHSTANDING THIS
PRESSURE.
See separate Section, “Drawing Package” on page 133, located at the back
of this manual, for the required plumbing specifications. The appropriate
plate drawing provides available plumbing specifications, both standard and
optional.
For example:
❑
Suction, victaulic and/or flange-type
❑
Discharge, typically flange-type
Various flanges and manifolding are also available. Contact Hale Products
at 610-825-6300 for additional information.
7.5
FLUID LEVELS
To meet various shipping regulations, ALL fluids within the pump and gear-
box assemblies are drained prior to shipping from the factory.
IMPORTANT !
AT INSTALLATION AND BEFORE OPERATING FOR THE FIRST TIME, OIL
MUST BE ADDED TO THE GEARBOX TO THE APPROPRIATE LEVELS. FOR
THE PROPER OIL TO USE AND QUANTITY REQUIRED, SEE SECTION 4: PRE-
VENTIVE MAINTENANCE, HEADING “REPLACE GEARBOX OIL” ON PAGE 58.
7.6
LINKAGE DESIGN FOR TRANSFER VALVE
Proper linkage design and installation is critical to valve actuation. To maxi-
mize the available actuation force on a remote valve, the linkage lines
should be as straight as possible.
It is recommended that the pull rod lines do not exceed a 10° line of travel
(see Figure 7-3: "Adjustable Valve Linkage Guidelines-- Top View" on 123).
Also, limit the number of bends to minimize flexing of the remote control
rod(s) (see Figure 7-4: "Adjustable Valve Linkage Guidelines-- Side View"
on 123).
Actual installed actuation force is dependent upon many factors:
Содержание Silencer AP Series
Страница 6: ...Overview 6 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 22: ...Introduction 22 Section 2 Introduction Hale Products Inc May 2006 Rev B...
Страница 32: ...Accessories Options 32 Section 2a Accessories Hale Products Inc May 2006 Rev B...
Страница 66: ...Preventive Maintenance 66 Silencer Series Booster Pump p n 029 0020 83 0...
Страница 124: ...Installation 124 Basic Installation Hale Products Inc August 06 Rev B...
Страница 143: ...143 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A Cavitation...
Страница 144: ...Cavitation 144 Appendix F Cavitation Hale Products Inc Nov 2005 Rev A...