DUAL DRYER SYSTEM
INSTALLATION/SERVICE
MANUAL (L31279)
®
PROBLEM
CAUSE
REPAIR
Heater element inoperable
Wrong voltage of element installed
Verify correct element or valve is being
used. (12 VDC vs 24 VDC).
Electrical power not present at heater
element
Check for power and ground with ignition
in “RUN” position.
Heater element not functioning
Perform operation check. Replace heater
element as needed.
Consep ADV inoperable
Electrical power not present at ADV
Check for power and ground with ignition
in “RUN” position.
Consep ADV manual drain button inoperable
Debris collected around return spring
Flush with a non-residual cleaner and
compressed air.
Troubleshooting (cont’d)
Suggested Maintenance Schedule
Maintenance
Interval
Maintenance
Recommended
Daily
Ensure purge valve operation. Drain
air system.
Weekly
Drain GeminiMDx purge tank and
air tanks.
Monthly
Operational check of all
GeminiMDx functions.
Every Two Years
Replace cartridge canisters.
Every Summer
Ensure discharge line temperature
is <170°F
Every Winter
Check heater element operation.
Refer to Operational Check Section
Page 12.
The maintenance intervals are dependent on
the operation conditions. The following is only a
suggested service interval for general installations.
One Year or 30,000 Miles, whichever
comes first
If the suggested interval is too long or too short
for the particular application, adjust accordingly
with the manufacturer’s specifications.
During maintenance, the internal parts must be
cleaned, inspected and/or replaced. Refer to Part
Service Kit(s) on the following page.
The Consep must be inspected periodically for
proper operation. The interval between inspections
is determined by the type of service. High
compressor duty cycles and high temperatures can
cause a build-up of carbon in the condenser, drain
valve and filter.
Page 14
Содержание GeminiMDx
Страница 1: ...INSTALLATION SERVICE MANUAL High Capacity Dual Dryer System...
Страница 27: ...inside back cover blank...