Foil 75
9
Drive Control Units
8) VMN HIGH
Test in rest state;
If contactors are open, voltage at VMN connection normally amounts to 50% VBatt. If
this voltage value is exceeded (> 70% VBatt), an alarm is output. Possible causes:
a)
A direction contactor is permanently closed since mechanically blocked
or permanently driven (incorrect wiring of contactor coil)
b)
Short-circuit between field and armature winding of motor
(disconnect cable at connection VMN, switch on, error disappears, repair motor)
c)
Incorrect connection of motor cable (check field and armature winding)
d)
Power circuit of controller defective (free wheeling or braking diodes short-
circuited) (disconnect cable at connection VMN, switch on, error persists,
replace controller)
9.1 ATECH / ZAPI
– DC Motor
Содержание Scrubmaster B 115 R
Страница 26: ...Foil 26 3 Technical Data...
Страница 27: ...Foil 27 3 Technical Data...
Страница 28: ...Foil 28 3 Technical Data...
Страница 51: ...Foil 51 7 Mechanical Components 7 1 Squeegee Fig 7 1...
Страница 53: ...Foil 53 7 Mechanical Components 7 1 Squeegee Fig 7 2 Fig 7 3...
Страница 58: ...Foil 58 7 Mechanical Components 7 3 1 Cylindrical Brush Head Fig 7 9 Fig 7 8 Fig 7 7 1...
Страница 59: ...Foil 59 7 Mechanical Components 7 4 Brush Head Lifting Unit...
Страница 60: ...Foil 60 7 Mechanical Components 7 4 Brush Head Lifting Unit...
Страница 61: ...Foil 61 7 Mechanical Components 7 4 Brush Head Lifting Unit...
Страница 102: ...Foil 102 10 1 Service Intervall 3 3 1 1 Fig 10 2...
Страница 104: ...Foil 104 11 Brakes 11 1 Adjustment of Brake DC Motor...
Страница 108: ...Foil 108 12 1 Option Silence Kit...
Страница 109: ...Foil 109 12 1 Option Silence Kit...
Страница 112: ...Foil 112 12 3 Option Chemical Dosage...
Страница 113: ...Foil 113 12 3 Option Chemical Dosage...
Страница 114: ...Foil 114 12 3 Option Chemical Dosage...
Страница 115: ...Foil 115 12 3 Option Chemical Dosage...
Страница 116: ...Foil 116 12 3 Option Chemical Dosage...
Страница 117: ...Foil 117 12 3 Option Chemical Dosage...
Страница 118: ...Foil 118 12 3 Option Chemical Dosage...
Страница 119: ...Foil 119 12 3 Option Chemical Dosage...
Страница 120: ...Foil 120 12 3 Option Chemical Dosage...
Страница 121: ...Foil 121 12 3 Option Chemical Dosage...
Страница 122: ...Foil 122 12 3 Option Chemical Dosage...
Страница 124: ...Foil 124 12 4 Option Scrubbing Vacuum Tool...
Страница 125: ...Foil 125 12 4 Option Scrubbing Vacuum Tool...
Страница 126: ...Foil 126 12 4 Option Scrubbing Vacuum Tool...
Страница 127: ...Foil 127 12 4 Option Scrubbing Vacuum Tool...
Страница 131: ...Foil 131 14 Notes...
Страница 132: ...Foil 132 14 Notes...
Страница 133: ...Foil 133 14 Notes...