When the station is ON and the
control card is in the station, the
data entry procedure is:
a. Hold the
button down for at least one
second.
b. The current temperature setting will be
displayed, then the
hundreds
digit will begin
to flash. This indicates that the station has
entered the temperature setting mode.
c. Follow steps 1-4 on the preceeding page.
NOTE:
When the
button is pressed for less than one second,
the current temperature setting is displayed.
●
Replacing the tip
Removing and inserting the tip:
Removing the tip: Hold the sleeve assembly
to remove the connector.
Remove the tip from the sleeve assembly.
(If the tip is hot, hold it with the heat-resistant
pad.)
Inserting the tip: Before inserting the tip ;
Insert the Tip ID end of the tip into the
process gate until the buzzer sounds once.
Hold head part and insert the tip into the
sleeve assembly. Push until the sleeve
assembly touches the ring round the tip;
at this point the tip should not be forced
further into the sleeve assembly.
Put the tip into the connector.
Insert the new tip firmly into the
connector. (If the tip is not properly
inserted,
will be displayed.)
There are no orientation requirements.
CAUTION:
The tip can be very HOT. Use the heat-resistant pad for
handling hot tips, but do not hold the hot portion of the tip,
even with the pad, for a long time.
8
Hold the sleeve assembly at the front to remove tip.
Hold these parts to insert tip into sleeve assembly.
Hold and squeeze this part to insert into the connector.