5-86
13. TOSHIBA PLC
13. TOSHIBA PLC
Available PLCs
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series is as follows:
•
PLC Transmission Parameter Setting
When setting parameters on the PLC, use the T series programmer and enter the
following data for system information “7. COMPUTER LINK.”
Select PLC Type
PLC
Unit/Port
Connection
T series
T series
Computer link port on CPU
RS-422
[Wiring Diagram 1]
Item
Setting on PLC
V7 Comm. Parameter Setting
Baud rate
19200 bps
19200 bps
Port
01
1
Parity
Odd
Odd
Transmission code
Data length
8
8
Stop bit
1
1
Station number
1
Baud rate
19200 bps
Parity
Odd
Data length
8 bits
Stop bit
1 bit