4
1. Ethernet
4-47
Netw
Errors during Macro Command Execution
The execution result of macro commands SEND/EREAD/EWRITE is stored in system
memory address $s515.
•
System memory address: $s515 (response to the request)
Code
Contents
Solution
0
Normal
200 - 2000
Communication error
Refer to “Communication Errors.”
−
30
Timeout
Check if an error is occurring to the target V7.
−
31
The number of words being sent exceeds
the limit.
Check the number of words that can be sent in macro
editing.
−
32
Specified table not used
Check the setting on the network table.
−
33
Cannot use the send command.
Check the macro command in macro editing.
−
34
Specified table being used
Check that system memory address $s514 is set. If
not, reduce the frequency of communications.
−
35
Cannot process due to short memory
Check the memory space at the target station.
−
36
Illegal receive packet bytes
Check the requested number of words.
−
37
Memory access error
Check the setting of the requested memory.
−
38
Macro setting error
Check the macro setting.