5
5. INITIAL SETUP
Connecting components
●
How to attach the tip
1. Slide off the flux protector and loosen the tip lock screw.
2. Insert a tip. Tighten the tip lock screw and reinstall the flux protector.
Replace the iron tip when it is cold.
If you need to replace the hot iron tip, always use a heat-resistant pad
.
Connecting cable
to HAKKO FU-500
②
Loosen
④
Tighten
①
Slide
③
Insert the tip
⑤
Reinstall
HAKKO FU-600
HAKKO FU-6001
18
is displayed and a buzzer sounds if the iron cable
is not attached to the station or wrong soldering iron
is connected.
10. ERROR MESSAGES
●
Sensor error
●
Low-temperature alarm
tolerance error
Example:
350°C (400°C – 50°C)
Low-temperature alarm tolerance
Set temperature
●
Soldering iron error
When there is possibility that a failure has occured
in the sensor or heater (including the sensor circuit),
is displayed and a buzzer sounds.
If the tip temperature falls below the low-temperature
alarm limit, is displayed and a buzzer sounds.
When the tip temperature rises above the low-
temperature alarm limit, a buzzer will stop.
●
Heater terminal short
circuit error
●
System error
When a system error occurs such as data flash,
the soldering iron is immediately de-energized and
is displayed.
is displayed and a buzzer sounds when the tip
inserted incorrectly, an incompatible tip is inserted,
or a foreign object has found its way into the connector.
●
Abnormally high
temperature error
When the tip temperature exceeds the temperature
setting plus 50℃ and this high temperature state lasts for
10 seconds or longer, the soldering iron is immediately
de-energized and is displayed and a buzzer sounds.
Note that the system will not recover from the error
status even if the high temperature state is corrected.
(The error status can be canceled only by turning
the power off.)
Pin No.
1
2
3
4
5
6
Signal name
TxD
RxD
Iron_Ready
Iron_GND
Iron_GND
Iron_Vcc
I/O
Out
In
Out
Out
Function
Outgoing data
Incoming data
HAKKO FU-600 Ready signal
HAKKO FU-600 GND
HAKKO FU-600 Vcc (5V)
Connecting cable (6-pole 6-core modular cable)
Iron cable
If any of the errors occur, the Ready signal output to the HAKKO FU-500 will be “Not Ready”.
Iron_Ready signal
output equivalent circuit
30V, less than 100 mA
Iron GND
Recommended Iron_Ready signal
connection diagram
External equipment
Iron_Ready
Iron_Vcc
910
Iron GND
Make sure that there is no clearance between the tip and the hole of the flux protector.
Use a hex wrench of 2.5 mm.
※Do not touch this screw during iron tip replacement.
CAUTION
CAUTION
CAUTION