5

5. INITIAL SETUP

Connecting components

How to attach the tip

1. Slide off the flux protector and loosen the tip lock screw. 

2. Insert a tip. Tighten the tip lock screw and reinstall the flux protector.  

Replace the iron tip when it is cold. 

If you need to replace the hot iron tip, always use a heat-resistant pad

Connecting cable

to HAKKO FU-500

Loosen

Tighten

Slide

Insert the tip

Reinstall

HAKKO FU-600

HAKKO FU-6001

18

          is displayed and a buzzer sounds if the iron cable

is not attached to the station or wrong soldering iron

is connected.

10. ERROR MESSAGES

Sensor error

Low-temperature alarm

    tolerance error

Example:

350°C (400°C – 50°C)

Low-temperature alarm tolerance

Set temperature

Soldering iron error

When there is possibility that a failure has occured

in the sensor or heater (including the sensor circuit),

          is displayed and a buzzer sounds.

If the tip temperature falls below the low-temperature

alarm limit,          is displayed and a buzzer sounds.

When the tip temperature rises above the low-

temperature alarm limit, a buzzer will stop.

Heater terminal short

    circuit error

System error

 

When a system error occurs such as data flash,

the soldering iron is immediately de-energized and

          is displayed.

          is displayed and a buzzer sounds when the tip

inserted incorrectly, an incompatible tip is inserted,

or a foreign object has found its way into the connector.

Abnormally high

    temperature error

 

When the tip temperature exceeds the temperature

setting plus 50℃ and this high temperature state lasts for

10 seconds or longer, the soldering iron is immediately

de-energized and           is displayed and a buzzer sounds.
Note that the system will not recover from the error

status even if the high temperature state is corrected.

(The error status can be canceled only by turning

  the power off.) 

Pin No.

1
2
3
4
5
6

Signal name

TxD
RxD
Iron_Ready
Iron_GND
Iron_GND
Iron_Vcc

I/O

Out

In

Out

Out

Function

Outgoing data
Incoming data
HAKKO FU-600 Ready signal
HAKKO FU-600 GND

HAKKO FU-600 Vcc (5V)

Connecting cable (6-pole 6-core modular cable)

Iron cable

If any of the errors occur, the Ready signal output to the HAKKO FU-500 will be “Not Ready”.

Iron_Ready signal

output equivalent circuit

30V, less than 100 mA

Iron  GND

Recommended Iron_Ready signal

connection diagram

External equipment

Iron_Ready

Iron_Vcc

910

Iron  GND

Make sure that there is no clearance between the tip and the hole of the flux protector.

Use a hex wrench of 2.5 mm. 

※Do not touch this screw during iron tip replacement. 

CAUTION

CAUTION

CAUTION

Содержание FU-600

Страница 1: ...661 294 0096 Toll Free 800 88 HAKKO 4 2 5 5 6 http www hakkousa com HONG KONG HAKKO DEVELOPMENT CO LTD TEL 2811 5588 FAX 2590 0217 http www hakko com hk E mail info hakko com hk SINGAPORE HAKKO PRODU...

Страница 2: ...resistance Tip to ground potential Cord length Total length 1 Weight 1 130 24V mV 3 m 9 8 ft 186mm 7 3 in 2 160mm 6 3 in 3 124g 0 27 lb 4 37 oz 126g 0 28 lb 4 44 oz 3 163g 0 36 lb 5 75 oz 165g 0 36 lb...

Страница 3: ...mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should...

Страница 4: ...a tip with a larger thermal capacity CHECK Is the setting value for the low temperature alarm tolerance too low ACTION Increase the setting value Heater terminal short circuit error is displayed CHECK...

Страница 5: ...ACTION See Checking the iron cable for breakage and Check for a broken heater or sensor in page 17 Replace any faulty part Solder does not wet the tip CHECK Is the tip temperature too high ACTION Set...

Страница 6: ...g iron is immediately de energized and is displayed is displayed and a buzzer sounds when the tip inserted incorrectly an incompatible tip is inserted or a foreign object has found its way into the co...

Страница 7: ...EDURE Check for a broken heater or sensor Verify the electrical integrity of the heater and sensor Measure the resistance of the heater and sensor while at room temperature 15 to 25 59 to 77 It should...

Страница 8: ...U 6001 to the feeder unit The HAKKO FU 6001 maintenance After the HAKKO FU 6001is used for soldering the unit particularly the flux protector is heavily deposited with flux If you insert a tip into th...

Страница 9: ...emperature please work carefully Except where indicated always turn the power switch OFF and disconnect the power plug before performing any maintenance procedure WARNING Tip maintenance 1 Tip tempera...

Страница 10: ...etting for password If selecting the Partial choose whether or not the password function is needed when changing the set temperature the preset number and the offset value and set the password Select...

Страница 11: ...r when a sensor error or soldering iron error occurs either or is displayed The buzzer does not sound when error occurs The buzzer sounds when error occurs 06 Set temperature achieving alert setting I...

Страница 12: ...tial Restricted 0 60 sec 7 PARAMETER SETTING Select three letters Turn on the power switch while pressing the and button the station will enter the parameter setting mode When the display shows flashi...

Страница 13: ...tial Restricted 0 60 sec 7 PARAMETER SETTING Select three letters Turn on the power switch while pressing the and button the station will enter the parameter setting mode When the display shows flashi...

Страница 14: ...r when a sensor error or soldering iron error occurs either or is displayed The buzzer does not sound when error occurs The buzzer sounds when error occurs 06 Set temperature achieving alert setting I...

Страница 15: ...etting for password If selecting the Partial choose whether or not the password function is needed when changing the set temperature the preset number and the offset value and set the password Select...

Страница 16: ...emperature please work carefully Except where indicated always turn the power switch OFF and disconnect the power plug before performing any maintenance procedure WARNING Tip maintenance 1 Tip tempera...

Страница 17: ...U 6001 to the feeder unit The HAKKO FU 6001 maintenance After the HAKKO FU 6001is used for soldering the unit particularly the flux protector is heavily deposited with flux If you insert a tip into th...

Страница 18: ...EDURE Check for a broken heater or sensor Verify the electrical integrity of the heater and sensor Measure the resistance of the heater and sensor while at room temperature 15 to 25 59 to 77 It should...

Страница 19: ...g iron is immediately de energized and is displayed is displayed and a buzzer sounds when the tip inserted incorrectly an incompatible tip is inserted or a foreign object has found its way into the co...

Страница 20: ...ACTION See Checking the iron cable for breakage and Check for a broken heater or sensor in page 17 Replace any faulty part Solder does not wet the tip CHECK Is the tip temperature too high ACTION Set...

Страница 21: ...a larger thermal capacity CHECK Is the setting value for the low temperature alarm tolerance too low ACTION Increase the setting value Heater terminal short circuit error is displayed CHECK Is the ti...

Страница 22: ...mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should...

Страница 23: ...resistance Tip to ground potential Cord length Total length 1 Weight 1 130 24V mV 3 m 9 8 ft 186mm 7 3 in 2 160mm 6 3 in 3 124g 0 27 lb 4 37 oz 126g 0 28 lb 4 44 oz 3 163g 0 36 lb 5 75 oz 165g 0 36 lb...

Страница 24: ...www hakko com hk E mail info hakko com hk SINGAPORE HAKKO PRODUCTS PTE LTD TEL 6748 2277 FAX 6744 0033 http www hakko com sg E mail sales hakko com sg HEAD OFFICE 4 5 Shiokusa 2 chome Naniwa ku Osaka...

Отзывы: