8
・
DS (Drag Soldering) Mode
Drag soldering process
*
When selecting a program number, set the signal P7 (MSB) to 1.
*
The controller outputs either the status signal Form1 or Form2
(according to the setting made during program setting).
Program selection setup time : t
ps
>
5msec
Program selection hold time : t
ph
>
25msec
Start signal pulse width : t
sw
>
25msec
Iron move signal pulse width : t
msw
>
25msec
Iron stop signal pulse width : t
mew
>
25msec
Program No. (In)
Start solder feed (In)
Controller ready (Out)
Primary feed (Internal)
Primary back feed (Internal)
Unit down command (Out)
Upper limit detection (In)
Lower limit detection (In)
Primary heating (Internal)
Start continuous feed (Out)
End continuous feed (In)
Secondary feed (Internal)
Secondary back feed (Internal)
Secondary heating (Internal)
Tertiary feed (Internal)
Tertiary back feed (Internal)
Tertiary heating (Internal)
Status signal
:
Form1 (Out)
Status signal
:
Form2 (Out)
15
●
Selecting Parameter Set
When you select Parameter Set, you will enter Parameter Setting mode.
In this mode, you can specify the operation of the entire system.
1. Feed Speed (Specifying the feed speed in continuous feed mode)
0.1
-
99.9mm / sec
2. S-U Mode (Selecting a slide unit connection mode)
Internal (Int) or External (Ext)
When Internal Mode is selected, all upper/lower limit
detection signals from the robot will be ignored.
3. S-U Timeout (Specifying the slide unit upper/lower limit detection timeout)
5
-
99 sec
Parameter Set
Feed Speed
S-U Mode
S-U Timeout
Iron Connect
Iron Status
Exit
10.0
Int
30
Con
Rdy
Feed Speed
1
0.0mm / sec
Slide Unit
Connect Mode
Int Mode
Ext Mode
Slide Unit
Time - out
3
0 sec
t
ps
t
ph
t
sw
t
msw
t
mew
On
Off
On
On
On
On
On
Off
Off
Off
Off
Off
Run