6. SETTING PARAMETERS
To make this product more convenient to use, the HAKKO FT-802 has the following parameters
which can be set. The parameter settings can be changed to suit your use environment.
•
Password setting
Setting a password allows you to lock the settings
for the output values and parameter values.
•
High output setting
*
The high output function for the blade output can
be enabled or disabled.
•
Output upper limit setting
*
An upper limit for the blade output can be set to
prevent the output from being set above the limit
value.
* When stripping is difficult by wire diameter and
composition, use a high output mode.
•
Auto sleep enable/disable setting
The auto sleep function can be enabled or disabled.
•
Auto sleep time setting
Auto sleep saves the set output by approx. 50%
and reduces the blade temperature to conserve
power consumption.
•
Auto shutoff enable/disable setting
The auto shut-off function can be enabled or
disabled.
•
Auto shutoff time setting
After the set time has elapsed, the output will be
switched off and the unit will enter standby mode.
or
or
to
to
to
to
or
or
or
: Disabled
: Disabled
: Enabled
(
min.
)
: Enabled
(
min.
)
: Partially
enabled
: Disabled
: Enabled
or
: Disabled
: Enabled
: Time until
effective
: Time until
effective
: Disabled
: Enabled
: Enabled
(3 digit)
*1. “High output setting” and “Output upper limit setting” are displayed when “1” or “2” is selected in “Password setting”.
*2. “Auto sleep time setting” is displayed when “1” is selected in “Auto sleep enable/disable setting”.
*3. “Auto shutoff time setting” is displayed when “1” is selected in “Auto shutoff enable/disable setting”.
Parameter
number
LED display
Set details
Initial value
Settable in 5% intervals
Password
setting
Output upper
limit setting*
1
Auto sleep
enable/disable
setting
Auto shutoff
enable/disable
setting
Auto shutoff time
setting*
3
Auto sleep time
setting*
2
High output
setting*
1