Instruction Manual
■
Packing List
HAKKO 192
1
Temperature sensors
10
Ring plate
1
Ground clip
1
Midzet fuse (5A)
1
Conduction wire
1
Instruction manual
1
■
Precautions
■
Specifications
Midzet fuse (5A)
Ground clip
Display
Conduction wire
Power cord
Power plug
Receptacle
Fuse holder
Power switch
Conduction plate
Select switches
Monitor
output
Ground
terminal
■
Part Names
Handle the temperature sensor carefully. The temperature sensor is
extremely thin ø0.2 and may break if pressed with too much force.
The measuring point on the temperature sensor has been specially
processed, but repeated measurements will cause it to wear out. Replace
it promptly to ensure the accuracy of measurements.
When there is flux on the terminal, wipe it away with a cloth that has been
moistened with alcohol. Do not use paint thinner or benzene.
Before measuring, coat the soldering iron tip with fresh solder. This is
necessary to ensure proper contacting between the tip, the temperature
sensor, and the conduction plate.
Instead of the over range code –1 , a value will sometimes be displayed
when the tip is not touching the conduction plate during voltage
measurement. This is normal.
During voltage and resistance measurement, make sure that the power
cord has been inserted into a grounded (3-hole) outlet.
When voltage and resistance measurements are greater than the
prescribed values, check the tip and make sure the fastening screws of
soldering iron are not loose, then measure again.
1.
2.
3.
4.
5.
6.
7.
Resolution
Measurement range
Precision
Sensor
Resolution
Measurement range
Accuracy
Conforms to MIL-STD-2000
Resolution
Measurement range
Accuracy
Liquid crystal display (LCD)
Over range
Temperature
Voltage
Resistance
Burn out
1W
200 (W) 50 (H) 120 (D) mm
7.9 (W) 2.0 (H) 4.7 (D) in.
Approx.1.1 kg/2.4 lbs.
0 to 40
°
C (32 to 104
°
F), 20 to 90% RH, no dew
1
°
C/1
°
F
0 ~ 600
°
C/0 ~ 1200
°
F
±
3
°
C (in 300 ~ 500
°
C range)
±
6
°
F (in 572 ~ 932
°
F range)
K (CA) thermocouple
0.1 mV
0 ~ 90 mV (AC)
±
(5% of r 1 digit)
0.1
0 ~ 90
±
(5% of r 1 digit)
3 /
2
digits
1 mV/
°
C,
°
F
10 mV/mV
10 mV/
-7 V (max.)
Temperature
Voltage
Resistance
Display
Monitor output
Power consumption
Dimensions
Weight (w/o cord)
Operating environment
Thank you for purchasing the HAKKO 192 soldering tester.
Please read this manual before operating the HAKKO 192.
Keep this manual readily accessible for reference.
The HAKKO 192 cannot be used with ungrounded soldering irons.
Ground the soldering iron by plugging it into a grounded (3-hole)
outlet.
1
Ring plate