5

(1)In case of connecting the flexible

hose with the outlet, tighten the

hose with quick release band.

《PIPING》 

Quick release band

Outlet

Flexible hose

(2)In circular system use, after removing the plate damper, connect the flexible hose and tighten

with quick release band.Use flanged damper to control air volume during circulation.

(available flanged damper :  PPD0075 or PSD0075)

CAUTION

Use suitable flexible hose
according to temperatures
of hot air. Otherwise it may
cause fire.

Gasket

Flanged damper

Quick release band

Bolt

Flexible hose  

* Refer  to  specifications  on  diameters  of  the  inlet

and the outlet.

* Fix  a  hose  connection  or  a  flanged  damper  with

the inlet by four bolts. 

(Quick release band and flexible hose are supplied

as optional parts.)

P

.C.D

96

φ7

5

The dimensions of the inlet

(Picture without the inlet pipe)

4−M5

Содержание HAP1012

Страница 1: ...ing our product Read the instructions before use and keep in the convenient place for future reference Please confirm the following on delivery Check if the name plate is correct as you ordered Check...

Страница 2: ...shock or burns Do not take off the side cover during operation Water may cause short circuit electric shock or failures Do not pour water at the body or the control panel Temperature around the exit o...

Страница 3: ...und It may cause electric shock or failures Do not heat steamy air Otherwise it may cause electric shock or failures The device is designed only for indoor use Do not use outdoors Otherwise it may cau...

Страница 4: ...00710 Power 100V 50 60Hz Heater capacity 1 2kW Temperature range ofair at the exit of outlet 20 of environmental temperature No air circulation 30 40 with the damper full open 60 80 with the damper cl...

Страница 5: ...0 40 Relative humidity R H 80 or less No explosive or corrosive gases Indoor without rain or wind Little dust Do not set the device in closed space Keep the inlet 50mm or more from the wall Flat hard...

Страница 6: ...e during circulation available flanged damper PPD0075 or PSD0075 CAUTION Use suitable flexible hose according to temperatures of hot air Otherwise it may cause fire Gasket Flanged damper Quick release...

Страница 7: ...ug is connected into the socket and the power breaker is turned on Check if feeding voltage is as much as 100V No air comes out Preset temperature of the controller is too low Increase the preset temp...

Страница 8: ...3890806 Japan TEL 81 26 275 0121 FAX 81 26 275 4878 HAKKO ELECTRIC THERMAL DEVICE SHANGHAI CO LTD No 512 Yutang Rd Songjiang Shanghai 201600 China TEL 86 21 5774 3121 FAX 86 21 5774 1700 HAKKO THAILAN...

Отзывы: