3
1. MAIN SPECIFICATIONS
80
Distance between fixing holes
(50)
473
(38)
(561)
322
Inlet pipe
215
φ73
Outlet
Movable plate
damper
153
Distance between fixing holes 500
520
Fixing bolt for the inlet
4−M5、P.C.D.96
260
365
53
(280)
52
(to the flange of the blower)
(20)
Inlet of air to
cool the blower
Movable plate damper
2P plug with
grounding terminal
Inlet
3m power cable
4-φ7
×
14 Fixing hole
pipe with the
diameter 75㎜
DIMENSIONS OF PARTS
2. NAMES OF PARTS
Handle
Outlet
Side cover
Blower
Control panel
Hanger for
power cable
Power cable
Movable plate damper
Inlet
FRONT
BACK
Product No.
HAP1012
Product code
00700710
Power
100V (50/60Hz)
Heater capacity
1.2 kW
Temperature range ofair at the exit of outlet
20℃ of environmental temperature. No air circulation
30 〜 40 ℃ (with the damper full open)
60 〜 80 ℃ (with the damper closed)
Temperature range set by the thermostat
33 〜 120 ℃
Air volume(50/60Hz as reference)
3.9/4.6
裙
/min (with the damper full open)
1.2/1.5
裙
/min (with the damper closed)
Air volume control
A movable plate damper controls air inlet.
Noise at the maximum of air volume
68 dB
The diameter of the inlet
φ 75mm (SPCC pipe)
The diameter of outlet
φ 73mm (Stainless steel pipe)
Temperature range of air at the inlet
-10 ℃〜 100 ℃
Weight
24 kg
Power cable
3m Flexible cable (VCTF) with plug
5.4 / 6.2
裙
/min (50/60Hz)
0.63 / 0.91 kPa (50/60Hz)
100V 0.15 kW (50/60Hz)
Maximum air volume
Maximum static pressure
Blower capacity
Blower specifications