The tank must be installed and operated
in a frost free environment.
At the installation location, suitable electrical and water supply and sewage sys-
tem must be ensured, and before mounting, the structure of the wall must also
be checked by an architect for compliance.
We recommend the following solutions for mounting the appliance:
• Horizontal levelled fl oor to ensure the absolute vertical position of the appliance.
Vertical adjustment can be achieved by appropriately adjusting the three legs of
the appliance.
• The appliance must be installed in such way that a clearance of min. 200 mm
must be left from the wall and at least 600 mm gap must be ensured between the
electrical safety cover and the wall or any other building structural component, to
allow removal of the service cover and cleaning the inside of the container.
• To decrease heat loss attributable to the hot water pipe, the appliance should be
installed the closest possible to the hot water withdrawal locations. For larger dis-
tances, the hot water pipe must be provided with thermal insulation.
5. CONNECTION TO THE WATER NETWORK AND
HEAT EXCHANGER
The tank and assemblies required for its operation must be connected to
the water network and heat exchanger according to Figure 10.3.
5.1.
It is forbidden to connect the appliance using a hose.
For cold and hot water connections, steel or red copper pipe rated for 0.6 MPa
nominal pipeline pressure, heat resistant plastic pipe rated up to min. 100 °C or
fl exible connection may equally be used. When connecting to a copper pipeline,
the use of insulating spacers is compulsory. One spacer must be inserted on the
hot water pipe of the container immediately, while the other one on the cold wa-
ter pipe, between the installed assemblies and the copper water pipeline. If no
spacer is used at the connections, we neither provide guarantee for failures at-
tributable to the corrosion of the threaded tank pipes, nor assume liability for
damages caused by the same.
The spacer is not included; you can order it under the following part number:
• 3/4” spacer: 1252122513
To expose the container to pressures
higher than the allowed operating pressure
it is forbidden and dangerous!
gépkönyv IND-IDExxxS ErP 1221114245-01.indd 21
2018.08.13. 11:45:56
Содержание IDE100S ErP
Страница 101: ...3 101 Jegyzet gépkönyv IND IDExxxS ErP 1221114245 01 indd 101 2018 08 13 11 46 11 ...
Страница 102: ...2 102 IDE S ErP IND S ErP gépkönyv IND IDExxxS ErP 1221114245 01 indd 102 2018 08 13 11 46 11 ...
Страница 103: ...3 103 gépkönyv IND IDExxxS ErP 1221114245 01 indd 103 2018 08 13 11 46 12 ...