Haivision MB6 Скачать руководство пользователя страница 1

MB6 and MB21 Multichannel 
Chassis

Installation Guide v2.0

HVS-ID-IG-MB6-MB21-20
Issue 01

Содержание MB6

Страница 1: ...MB6 and MB21 Multichannel Chassis Installation Guide v2 0 HVS ID IG MB6 MB21 20 Issue 01...

Страница 2: ...ment including but not limited to lost revenue lost data claims by third parties or other damages If you have comments or suggestions concerning this Installation Guide please contact Technical Public...

Страница 3: ...fic mechanism lock and key or other security device ATTENTION Ce produit est destin tre install dans une zone d acc s restreint Les zones d acc s limit sont prot g es par un m canisme sp cifique une s...

Страница 4: ...cessary users will have to resolve these issues at their own expense Avis relatif aux appareils de classe A FCC Toute modification de l quipement sans l autorisation de Haivision peut entra ner sa non...

Страница 5: ...orpads and workbench pads Improper handling and or installation practices may VOID the warranty CAUTION When handling components or when setting switch options always use an antistatic wrist strap con...

Страница 6: ...9 MB6 Installation 9 MB6 Chassis Removable Fan Tray 12 MB6 Chassis Indicators and Alarms 12 Replacing the MB6 Chassis Fan Tray 13 F MB6X RAC and F MB6X DC Chassis Power Components 14 Replacing the F...

Страница 7: ...6 and MB21 Multichannel Chassis Installation Guide v2 0 Issue 01 7 Physical Characteristics MB21B F MB21B R 26 Physical Characteristics MB21X F MB21X R 27 Replacement Part Ordering Information 27 For...

Страница 8: ...nt power supplies allow for in service blade replacement and incorporate fan management circuitry to minimize fan noise MB6 series and MB21B F MB21B R enclosures can be populated with any combination...

Страница 9: ...one of two ways 1 free standing on a desktop or rack shelf or 2 fastened directly to a rack using support brackets supplied WARNING To prevent electric shock do not remove the cover of the MB6 chassis...

Страница 10: ...hes to the ON 1 position On the MB6 RAC the PSU Status LEDs will turn green indicating that the chassis is powered up In the front of either chassis the Status LEDs will start blinking green indicatin...

Страница 11: ...Connect the screw marked to a 28 VDC power source and the screw marked to the neutral wire The maximum width of the terminal lug is 0 32 inches 8 13 mm The minimum wire gauge is 16 AWG Figure 5 F MB6...

Страница 12: ...Power LED Fan LED Audible Alarm Indication OFF OFF OFF No power to chassis Solid Green Solid Green OFF Power applied to chassis and no issue fault is reported Solid Green Solid Red ON Chassis Power O...

Страница 13: ...nt 1 Turn the fan tray knob clockwise to unlock the fan tray 2 Remove the fan tray by pulling it away from the chassis Set it on an antistatic surface or repack it in packing materials 3 Insert a new...

Страница 14: ...vision If field serviceability is a requirement we recommend that you keep a second F MB6X MED chassis available on the premises Figure 8 F MB6X RAC Chassis Rear View showing removable PSUs and PDU Fi...

Страница 15: ...DC Chassis Power Distribution Unit The PDU is not hot swappable so you must power down the chassis to replace the PDU To replace the F MB6X RAC or F MB6X DC PDU 1 Turn off all PDU power switches 2 Di...

Страница 16: ...redundant MB21 chassis that supports Makito X products only and any future products that need 12V power only The F MB21X R chassis provides field replaceable fans dual power supplies and a station al...

Страница 17: ...any combination of up to 21 Makito X classic Makito Barra cuda and Torpedo mini blades Figure 12 F MB21B R Chassis Rear View Each socket on the PDU Power Distribution Unit powers a pair of PSUs Power...

Страница 18: ...oved or lifted by two persons The handles on the front of the chassis should be used for a solid grip 4 Using a 5 16 hex nut driver remove the hex head screws E and F in Figure 13 below holding the su...

Страница 19: ...r extend the support brackets you may safely remove the two screws at po sition E on each side 9 Using a 5 16 hex nut driver tighten the four screws at position F on each support bracket 10 If needed...

Страница 20: ...r Power On Off switches are On In the front of the chassis the Status LEDs will start blinking green indicating that the encoders decod ers gateways are booting up 4 Wait until the Status LEDs stay so...

Страница 21: ...e button A B C E D Push button to mute Fan Tray Audible Alarm Fan Tray Power LED Fan Tray Bi Color Status LED Green Fan Tray Status OK Red Fan Tray Status Problem RTU Terminal Connector 6 pins Fan Tra...

Страница 22: ...sis Solid Green Solid Green OFF Power applied to chassis and no issue fault is reported Solid Green Solid Red ON Chassis Power ON Fault s Detected The following faults will trigger the audible alarm a...

Страница 23: ...tray by turning them counter clockwise Note that the screws are spring attached to the panel 2 If an RTU cable is connected disconnect the cable 3 Remove the fan tray by pulling it away from the chas...

Страница 24: ...ith the PSU When this occurs you should replace the power supply CAUTION Refer to Antistatic Precautions on page 5 to prevent ESD damage to the equipment 1 Turn off the PSU to be replaced The alarm wi...

Страница 25: ...Power LED will show red to indicate an issue with the PSU When this occurs you should replace the power supply CAUTION Refer to Antistatic Precautions on page 5 to prevent ESD damage to the equipment...

Страница 26: ...Medical Grade 90 264VAC 47 63Hz F MB6X DC DC type 20 36 VDC 300 watt maximum all types Operating Temperature 0 C to 50 C 32 F to 122 F Non Operating Temperature 40 C to 70 C 40 F to 158 F Humidity up...

Страница 27: ...3Hz 600 watt maximum Operating Temperature 0 C to 50 C 32 F to 122 F Non Operating Temperature 40 C to 70 C 40 F to 158 F Humidity up to 95 non condensing MB6X F MB6X FAN MB6X Replacement fan unit P M...

Страница 28: ...n com support portal home Or you may use the phone numbers or email addresses listed below North America International Technical Support email Product Information email Toll Free 1 877 224 5445 option...

Страница 29: ......

Отзывы: