Table 1. Terminal Designation Descriptions.
Terminal Designation
Description
RC (see Note 1)
Power for cooling--connect to secondary side of cooling system
transformer
R (see Note 1)
Power for heating--connect to secondary side of heating system
transformer
C (see Note 2)
Common wire from secondary side of cooling system transformer
Y
Compressor contactor
G
Fan relay
Y2
Second stage cooling
O/B/W (see Note 3)
Changeover valve for heat pump systems or Heat relay
AUX/W2
Auxiliary heat relay for heat pump systems or Second stage heat relay
E
Emergency heat relay for heat pump systems
L (see note 4)
Equipment monitor for heat pump systems