background image

Important default settings 

User codes 

You can program up to 32 different user codes in to your ProGuard800 system. A user code 
has four numbers. For most system functionalities you have to enter your user code. 

User

Code

USER 1 MASTER 

1234

USER 32 INSTALL. 

1111

Zones 

The ProGuard800 has 33 safe zones. Zones 1-32 are meant for wireless sensors. Per zone 
one sensor can be registered. 

Zone

Type

Descriptor

1 to 2 

ENTRY/EXIT

DS831

3 to 9 

NORMAL

DS831

11 to19 

NORMAL

MS845

21 to 22 

FIRE

SD833 

23 to 24 

FLOOD

WD861 

25 to 26 

24 HOURS 

TS863 

Keyfobs 

Two kinds of Keyfob transmitters can be registered to your 

ProGuard800,

 the PR811 and the 

KR814. You can register up to 19 Keyfobs to the system. 

KR814 KEYFOB #1 to #10 

PR811 KEYFOB #11 to 19 

Keypads 

The ProGuard800 can be operated with at most four wireless keypads. Except for the cancel 
button the operation of the WK820 and the RC840 keypads is the same. 

RC840 KEYPAD #1 to #2 

WK820 KEYPAD #3 to #4 

ProGuard800™ 

- 14 -

Содержание ProGuard800 Series

Страница 1: ...PROGUARD 800 20213 20100604 PROGUARD800TM ALL RIGHTS RESERVED HAIBRAIN ENGLISH PROGUARD800 SERIES QUICK INSTALLATION GUIDE...

Страница 2: ...stone 6 mm Bit metal 4 mm x Marker x ProGuard800 set consisting of x Control panel x Motion sensor MS845 x Keyfob remote control KR814 x Door window sensor DS831 x Telephone cord with RJ11 Connectors...

Страница 3: ...ard800 Connecting the telephone cord 1 Get the enclosed telephone cord from the box and guide it through the hole on the back side of the central unit Connect the telephone cord to the left telephone...

Страница 4: ...anel When the control panel is in programming mode the first line always indicates the subject The second line always indicates the options With the keys you can step through the options With 9 you ca...

Страница 5: ...icate that the ProGuard800 is still activated when you enter your house it is recommended to equip the entrance door with a Door Window sensor with an entrance delay When entering the ProGuard800 indi...

Страница 6: ...ector between front and backside of the sensor Now move the screwdriver upward 2 Supply the Motion sensor with power by removing the red plate which separates the battery from the battery contacts 1 D...

Страница 7: ...er contact or with the DS831 by moving the magnet from or to the sensor or with the MS845 by generating some movement The details of the transmitter now appear on the LCD display of the central unit B...

Страница 8: ...ce the caps on the magnet and the sensor 5 The ProGuard800 has given a TAMPER ALARM for the DS831 when placing it Enter 1 2 3 4 on the Proguard800 when the caps have been replaced Placing the MS845 Wh...

Страница 9: ...the display now shows 1 KF1 REGISTER TRANSMIT 2 Press once again one of the keys of the KR814 the display now shows 1 KF1 REGISTER SAVE Press 9 to confirm You will now hear a long beeping sound 7 Pres...

Страница 10: ...d800 is now making a call If you pick up the telephone that is being called you will hear the following notification ProGuard800 alarm system system armed For the next message press 1 This notificatio...

Страница 11: ...he display now shows 4 USER CODES USER 20 NON_CTRL 4 Press 9 the display now shows USER 20 NON_CTRL 1 EDIT CODE 5 Press 9 the display now shows 1 EDIT CODE 0000 6 The cursor is located at the first nu...

Страница 12: ...ssing 9 followed by 1111 the display now shows MAIN MENU 1 STOP COMM 2 Press 94061 the display now shows 6 DISPLAY 1 ARM STATUS 3 Press 9 4 Press the display now shows 1 ARM STATUS DISPLAY ALWAYS 5 Pr...

Страница 13: ...stered Zone Type Descriptor 1 to 2 ENTRY EXIT DS831 3 to 9 NORMAL DS831 11 to19 NORMAL MS845 21 to 22 FIRE SD833 23 to 24 FLOOD WD861 25 to 26 24 HOURS TS863 Keyfobs Two kinds of Keyfob transmitters c...

Страница 14: ...N 9 3 TWO WAY AUDIO 9 ENABLED 5 EVENT OPTIONS 9 1 BURGLARY 9 1 RAPPORTAGE 9 ENABLED 9 d 2 RAPPORT HERST 9 ENABLED 9 d 3 TWO WAY AUDIO 9 ENABLED 9 d 2 FIRE 9 1 RAPPORTAGE 9 ENABLED 9 d 2 RAPPORT HERST...

Страница 15: ...9 d 7 KF CTRL 2 9 DISABLED 9 d 8 TEL CTRL 2 9 DISABLED 9 d 9 RANDOMIZE 2 9 DISABLED 9 d 10 PULSE TIME 2 9 2 MIN 9 d 11 DESCRIPT 2 9 DIMMER MODULE 9 2 HOUSE CODE 9 A HOUSE CODE 3 HA CONTROL 9 ENABLED...

Страница 16: ...ZI0488B 1 09...

Отзывы: